{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1110-3ED46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1110-3ED46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1110-3ED46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1110-3ED46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1110-3ED46-0AA0, molded case circuit breaker, 4-pole, 100 A at 40 °C, TM210 thermal-magnetic release, 75.6 kA interrupting at 240 V, IP40 front.","salesMarkdown":"## SENTRON 3VA1110-3ED46-0AA0 — MCCB for Line Protection The Siemens 3VA1110-3ED46-0AA0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection, carrying a continuous current rating of 100 A at 40 °C with no derating needed up to 50 °C — above that it drops to 98 A at 55 °C and 91 A at 70 °C, so if your panel ambient runs hot, that's the number to size against. Interrupting capacity hits 75.6 kA at 240 V, 52.5 kA at 415 V, and 11.9 kA at 690 V, which covers most industrial service-entrance and distribution panel fault duties. If you're freezing a BOM or managing a long-term project, the SENTRON 3VA platform is Siemens' main MCCB family, so replacement parts and accessories (auxiliary contacts, shunt trips, rotary handles) are standard catalog items. No second-source cross-reference needed — this is the primary line. ## Physical Fit & Panel Integration Dimensions: 130 mm tall, 101.6 mm wide, 70 mm deep — a 4-pole MCCB footprint that fits standard Siemens SENTRON mounting plates and panel cutouts.","metaTitle":"Siemens 3VA1110-3ED46-0AA0 SENTRON MCCB, 100 A, 4-Pole, 75.6","metaDescription":"Siemens 3VA1110-3ED46-0AA0 SENTRON molded case circuit breaker, 100 A at 40 °C, 4-pole, 75.6 kA interrupting at 240 V. TM210 release, IP40 front. Sourced to order; confirm pricing","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"101.6 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 500 V":"11.9 kA","at 690 V":"11.9 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"98 A","at 60 °C":"96 A","at 65 °C":"94 A","at 70 °C":"91 A","Depth [In]":"2.76 in","Width [In]":"4 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"4","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","design of the N-conductor protection":"without","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"600 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"N","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$143.51","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=316201&mlfb=3VA1110-3ED46-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1110-3ED46-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting capacity of 3VA1110-3ED46-0AA0 at 240 V?","answer":"75.6 kA at 240 V. It also delivers 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at 500 V and 690 V."},{"question":"What does the TM210 release designation mean?","answer":"TM210 means a thermal-magnetic release with a fixed 100 A thermal element and an adjustable magnetic trip — the '210' code indicates the 100 A rating level in Siemens' naming convention."},{"question":"Where can I buy 3VA1110-3ED46-0AA0 and get current pricing?","answer":"We source this part to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does this MCCB carry?","answer":"As a Siemens SENTRON product, it is designed to meet IEC 60947-2 and UL 489 standards for molded case circuit breakers. Specific RoHS, REACH, and CE declarations are available from Siemens' documentation portal using the order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1110-3ED46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1110-3ED46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}