{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1110-3EF36-0JA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1110-3EF36-0JA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1110-3EF36-0JA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1110-3EF36-0JA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 160, breaking capacity class N, 3-pole, line protection TM240, ATAM, In=100A, overload Ir=70A...100A, short-circuit Ii=5...10 x In, clamp connection, shunt trip (STL) 110-127V DC/AC.","salesMarkdown":"The Siemens 3VA1110-3EF36-0JA0 is a 3-pole IEC frame 160 molded case circuit breaker with a 25 kA breaking capacity at 415 V (class N). It is rated In=100 A continuous current, with an adjustable thermal overload protection range (Ir) of 70 A to 100 A and a fixed short-circuit magnetic trip (Ii) set at 5 to 10 times In. The breaker includes a shunt trip (STL) release for remote tripping, rated 110-127 V DC or AC 50/60 Hz. The adjustable Ir (70-100 A) lets you match the overload protection to the actual load cable or motor FLA without swapping the breaker body. ## Panel integration Clamp-type terminals accept copper or aluminum conductors without lug kits. The 3VA1 frame fits standard Siemens panelboard and switchboard mounting patterns. The shunt trip occupies the accessory slot on the left side; no additional wiring space is needed beyond the breaker's own line/load terminals.","metaTitle":"Siemens 3VA1110-3EF36-0JA0 Circuit Breaker, 100A, 25kA @ 415","metaDescription":"Siemens 3VA1110-3EF36-0JA0 IEC frame 160 circuit breaker, 25kA breaking capacity at 415V, 100A, with shunt trip. Current production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=53925&mlfb=3VA1110-3EF36-0JA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1110-3EF36-0JA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this breaker?","answer":"The rated ultimate breaking capacity (Icu) is 25 kA at 415 V AC, which is class N within the 3VA1 frame."},{"question":"What does the adjustable overload protection range cover?","answer":"The thermal overload Ir is adjustable from 70 A to 100 A, and the short-circuit magnetic trip Ii is fixed at 5 to 10 times In (500 A to 1000 A)."},{"question":"Where can I buy 3VA1110-3EF36-0JA0?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — it will be quoted against your order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1110-3EF36-0JA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1110-3EF36-0JA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}