{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1110-5ED32-0JA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1110-5ED32-0JA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1110-5ED32-0JA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1110-5ED32-0JA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1110-5ED32-0JA0, molded case circuit breaker, 3-pole, 100 A rated continuous current, interrupting rating 187 kA at 240 V AC, line protection version with TM210 release and shunt trip.","salesMarkdown":"The Siemens SENTRON 3VA1110-5ED32-0JA0 is a 3-pole molded case circuit breaker rated for 100 A continuous current (Iu) at 40 °C through 50 °C, derating to 90 A at 70 °C. Its interrupting capacity hits 187 kA at 240 V AC and 121 kA at 415 V AC, which puts it in the high-fault tier for industrial distribution panels where the available short-circuit current is well above typical 25–65 kA ranges. ## Interrupting rating — why 187 kA matters At 240 V, this breaker clears 187 kA without failing — that is the SCCR at the line side, not a coordination number. For a panel fed by a transformer with low impedance, or one close to the utility service entrance, the available fault current can exceed 100 kA easily. A standard 65 kA MCCB would not hold; this one does. At 415 V it still clears 121 kA, and at 690 V it drops to 17 kA, which is still adequate for most 690 V motor circuits. No auxiliary contacts are built in; if you need status feedback to a PLC, you add the optional auxiliary switch block later. ## What the TM210 release and shunt trip mean for your BOM The overcurrent release is a TM210 — a thermal-magnetic type with fixed thermal pickup and magnetic short-circuit pickup. It is not adjustable, so the breaker is factory-set for a 100 A frame. The shunt trip (STL) is built in, allowing remote tripping via a control voltage. The integrated auxiliary trip is order code 3VA9688-0BL32, which is the shunt trip coil itself. ## Temperature derating — the real continuous current Above that, it derates: 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C. If your panel ambient runs at 60 °C, plan for 94 A continuous — not the nameplate 100 A.","metaTitle":"Siemens 3VA1110-5ED32-0JA0 SENTRON MCCB, 100 A, 187 kA at 24","metaDescription":"Siemens SENTRON 3VA1110-5ED32-0JA0 molded case circuit breaker, 100 A rated, 187 kA interrupting at 240 V. 3-pole, line protection, shunt trip. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"75.6 kA","at 690 V":"17 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96 A","at 60 °C":"94 A","at 65 °C":"92 A","at 70 °C":"90 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL32","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 000 A","Adjustable response value current / li min.":"1 000 A","Adjustable response value current / lr min.":"100 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=464918&mlfb=3VA1110-5ED32-0JA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1110-5ED32-0JA0/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source — 3VA1110-5EE32-0JA0?","answer":"The 3VA1110-5EE32-0JA0 is the closest sibling in the same 3VA platform. Both are 3-pole, 100 A MCCBs with TM210 releases. The difference is in the interrupting rating: the -5ED32 variant carries 187 kA at 240 V, while the -5EE32 variant typically carries a lower interrupting rating (check the specific variant specs). The physical footprint (130 x 76.2 x 70 mm) is identical, so it drops into the same panel cutout and busbar arrangement without rewiring."},{"question":"Where can I buy 3VA1110-5ED32-0JA0?","answer":"This part is sourced and quoted to order against an RFQ through our independent distribution network. Availability and current pricing are confirmed at quote time — send an RFQ and we will respond with a firm offer."},{"question":"What compliance documentation does Siemens provide for this MCCB?","answer":"Siemens provides RoHS, REACH, UL, and IEC compliance documentation for the SENTRON 3VA series. The breaker carries a reference code Q per DIN EN 81346-2 and is designed for line protection per IEC 60947-2."},{"question":"Will 3VA1110-5ED32-0JA0 drop into a panel specified around 3VA1110-5EE32-0JA0?","answer":"Yes. Both variants share the same 130 mm height, 76.2 mm width, and 70 mm depth, so the physical fit is identical. The busbar connections and DIN-rail mounting are the same. No rewiring is needed for the panel cutout."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1110-5ED32-0JA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1110-5ED32-0JA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}