{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1110-5EE32-0AC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1110-5EE32-0AC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1110-5EE32-0AC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1110-5EE32-0AC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1110-5EE32-0AC0, 3-pole molded case circuit breaker, 100 A, TM220 thermal-magnetic release, line protection design.","salesMarkdown":"The Siemens 3VA1110-5EE32-0AC0 is a SENTRON 3-pole molded case circuit breaker rated 100 A at 40 °C with a TM220 thermal-magnetic release, designed for line protection. Its breaking capacity reaches 187 kA at 240 V, 121 kA at 415 V, and 75.6 kA at 440 V — numbers that tell you this breaker handles high-fault-current scenarios typical in industrial distribution without cascading upstream. Rated current holds flat at 100 A from 40 °C through 50 °C, then derates to 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C. The TM220 release combines a thermal bimetal for overload protection and a magnetic coil for short-circuit response; it's the standard choice for feeder and branch-circuit protection where you don't need electronic adjustability. Dimensions are 130 mm high, 76.2 mm wide, 70 mm deep — a standard 3-pole MCCB footprint that drops into SENTRON mounting bases and panel cutouts. The breaker ships with two HQ auxiliary switches built in, so you get status feedback without adding external contact blocks.","metaTitle":"Siemens 3VA1110-5EE32-0AC0 SENTRON MCCB, 100 A, 3-Pole, TM22","metaDescription":"Siemens 3VA1110-5EE32-0AC0 SENTRON molded case circuit breaker. 100 A rated, 3-pole, TM220 release. Breaking capacity 187 kA at 240 V. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"75.6 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"98 A","at 60 °C":"96 A","at 65 °C":"94 A","at 70 °C":"91 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA11105EE320AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM220","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a5bdd675614371a67fda1e96f59b9ffc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=217098&mlfb=3VA1110-5EE32-0AC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1110-5EE32-0AC0/alternatives.json"},"ai":{"faq":[{"question":"How do I get pricing and availability for 3VA1110-5EE32-0AC0?","answer":"Submit an RFQ. This part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"Will 3VA1110-5EE32-0AC0 drop into a panel specified for 3VA1110-5EF32-0AM0?","answer":"Both are 3-pole SENTRON MCCBs in the same physical footprint (130 x 76.2 x 70 mm), so mechanical fit is the same. The deciding difference is the release and rating: the 5EE32-0AC0 carries a TM220 release rated 100 A, while the 5EF32-0AM0 uses a different release. Verify the trip curve and ampacity match your coordination study before swapping."},{"question":"What compliance documentation does Siemens provide for this MCCB?","answer":"As a SENTRON product, the 3VA1110-5EE32-0AC0 carries CE marking and is designed to IEC 60947-2. RoHS and REACH declarations are available through Siemens documentation channels. UL/CSA listings vary by variant — confirm with the factory certificate for your specific order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1110-5EE32-0AC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1110-5EE32-0AC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}