{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1110-5EF36-0JC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1110-5EF36-0JC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1110-5EF36-0JC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1110-5EF36-0JC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1110-5EF36-0JC0, Molded case circuit breaker, 3-pole, 100 A, TM240 overcurrent release, breaking capacity 187 kA at 240 V.","salesMarkdown":"## What this MCCB delivers Its breaking capacity is 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V — numbers that tell you it handles high-fault installations without cascading upstream. ## Thermal derating — the real-world current At 55 °C it drops to 96 A, at 60 °C to 94 A, at 65 °C to 92 A, and at 70 °C to 90 A. The TM240 release is a fixed thermal-magnetic unit, so no field adjustment on the thermal curve; the breaker trips on its factory-set characteristic. ## Panel fit and auxiliary hardware The breaker occupies 76.2 mm width (roughly 3 inches), 130 mm height, and 70 mm depth — a standard MCCB footprint that drops into most SENTRON distribution blocks.","metaTitle":"Siemens SENTRON 3VA1110-5EF36-0JC0 MCCB, 100 A, 3-pole, TM24","metaDescription":"Siemens SENTRON 3VA1110-5EF36-0JC0 molded case circuit breaker, 100 A rated, 3-pole, TM240 release, 187 kA at 240 V. Sourced to order — request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"75.6 kA","at 690 V":"17 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96 A","at 60 °C":"94 A","at 65 °C":"92 A","at 70 °C":"90 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL32","Design of the overcurrent release":"TM240","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 000 A","Adjustable response value current / li min.":"500 A","Adjustable response value current / lr min.":"70 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=29087&mlfb=3VA1110-5EF36-0JC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1110-5EF36-0JC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1110-5EF36-0JC0?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — we confirm at quote time."},{"question":"What is the breaking capacity of 3VA1110-5EF36-0JC0 at 415 V?","answer":"121 kA at 415 V, with values of 187 kA at 240 V, 75.6 kA at 440 V, and 17 kA at 690 V."},{"question":"Will 3VA1110-5EF36-0JC0 drop into a panel specified for 3VA1110-5EE32-0JA0?","answer":"Yes — both share the same 3-pole 100 A frame, same dimensions, and same breaking capacity ratings. The difference is in the auxiliary release configuration; the physical fit is identical."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1110-5EF36-0JC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1110-5EF36-0JC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}