{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1110-6ED32-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1110-6ED32-0AB0","canonicalUrl":"https://aoctrl.com/siemens/3VA1110-6ED32-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1110-6ED32-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1110-6ED32-0AB0, Molded case circuit breaker, 4-pole, 80 A, TM210 release, 76 kA at 240 V, IP40 front.","salesMarkdown":"Its 4-pole construction handles three-phase plus neutral, and the interrupting ratings climb to 76 kA at 240 V AC — enough to clear high-fault scenarios in distribution panels without upstream coordination headaches. At 415 V the breaker still holds 53 kA, dropping to 32 kA at 440 V and 5 kA at 500 V or 690 V. That steep fall-off above 500 V means this variant is best suited for 240 V or 400/415 V lineups where the available fault current stays under 53 kA. The TM210 release is fixed thermal-magnetic — no electronic adjustment, no communication module, no voltage-trip or ground-fault monitoring. It is a straightforward line-protection breaker for panels where simplicity and reliability beat configurability. At 55 °C it derates to 78 A, then 77 A at 60 °C, 75 A at 65 °C, and 74 A at 70 °C. That flat top through 50 °C is useful for enclosures with moderate heat rise — no need to oversize for a warm panel. Height is 130 mm, width 4 in — a standard footprint for 4-pole MCCBs in North American and IEC panels. No undervoltage release or shunt trip is fitted on this order code — if you need those, this is not the variant.","metaTitle":"Siemens 3VA1110-6ED32-0AB0 SENTRON MCCB, 80 A, 4-Pole, 76 kA","metaDescription":"Siemens 3VA1110-6ED32-0AB0 SENTRON molded case circuit breaker, 80 A rated, 4-pole, 76 kA interrupting at 240 V. Active production, sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Height":"130 mm","at 240 V":"76 kA","at 415 V":"53 kA","at 440 V":"32 kA","at 500 V":"5 kA","at 690 V":"5 kA","at 40 °C":"80 A","at 45 °C":"80 A","at 50 °C":"80 A","at 55 °C":"78 A","at 60 °C":"77 A","at 65 °C":"75 A","at 70 °C":"74 A","Width [in]":"4 in","Trip indicator":"No","Number of poles":"4","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches HP","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"80 A","Rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA11106ED320AA0","Design of the auxiliary release":"without auxiliaryrelease","Ground fault monitoring version":"Without","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Design of the N-conductor protection":"Without","Max. rated operational voltage Ue with DC":"600 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"No","Adjustable response value current / lg min.":"80 A","Adjustable response value current / li max.":"800 A","Adjustable response value current / li min.":"800 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protection Function Of The Overcurrent Release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA11","Switching capacity class of the circuit breaker":"N","Max. rated operational current of the frame size":"100 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Mechanical service life (switching cycles) / typical":"15 000","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1022659&mlfb=3VA1110-6ED32-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1110-6ED32-0AB0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1110-6ED32-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1110-6ED32-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}