{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1110-6EE32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1110-6EE32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1110-6EE32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1110-6EE32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1110-6EE32-0AA0, molded case circuit breaker, 3-pole, 100 A, TM220 thermal-magnetic release, 220 kA interrupting at 240 V, line protection, IP40 front.","salesMarkdown":"The TM220 thermal-magnetic release handles overload and short-circuit curves without a separate trip unit — set it and forget it for fixed-threshold distribution panels. Interrupting capacity hits 220 kA at 240 V, dropping to 154 kA at 415 V and 121 kA at 440 V — still well above typical utility fault levels for most industrial services. At 690 V it holds 17 kA, so it's usable on 480Y/277 V or 600 V delta systems within that ceiling. The 3-pole footprint measures 76.2 mm wide, 130 mm tall, and 70 mm deep — a standard SENTRON 3VA frame that drops into existing 3VA panel cutouts without re-drilling. Rated 100 A from 40 °C through 50 °C; above that it derates linearly to 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C. The storage limits govern handling and warehousing, not running conditions.","metaTitle":"Siemens 3VA1110-6EE32-0AA0 SENTRON MCCB, 100 A, 3-Pole, 220","metaDescription":"Siemens 3VA1110-6EE32-0AA0 SENTRON molded case circuit breaker, 100 A, 3-pole, TM220 release, 220 kA at 240 V. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"220 kA","at 415 V":"154 kA","at 440 V":"121 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"98 A","at 60 °C":"96 A","at 65 °C":"94 A","at 70 °C":"91 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM220","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=227528&mlfb=3VA1110-6EE32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1110-6EE32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the width of 3VA1110-6EE32-0AA0?","answer":"76.2 mm (3 inches)."},{"question":"Will 3VA1110-6EE32-0AA0 drop into a panel specified around 3VA1110-5ED32-0AA0 without rewiring?","answer":"Both are 3-pole SENTRON 3VA frame MCCBs with the same 76.2 mm width, 130 mm height, and 70 mm depth — mechanical fit is identical. The difference is the overcurrent release: the -6EE32 carries a TM220 thermal-magnetic release, while the -5ED32 uses a different release variant. Verify the trip curve matches your coordination study before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1110-6EE32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1110-6EE32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}