{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1110-6EF36-0AC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1110-6EF36-0AC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1110-6EF36-0AC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1110-6EF36-0AC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1110-6EF36-0AC0, 3-pole molded case circuit breaker, 100 A rated at 40 °C, 154 kA breaking capacity at 415 V AC, TM240 thermal-magnetic release, line protection design.","salesMarkdown":"## SENTRON 3VA1110-6EF36-0AC0 — MCCB for Line Protection The Siemens 3VA1110-6EF36-0AC0 is a 3-pole SENTRON molded case circuit breaker (MCCB) designed for line protection, carrying a TM240 thermal-magnetic overcurrent release and a 100 A rating at 40 °C ambient. Above that it drops to 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C. Breaking capacity drops with voltage: 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at both 500 V and 690 V. It is a fixed-trip breaker for straightforward line protection where selectivity is set by frame size and cable impedance. Width is 76.2 mm (3 in), depth 70 mm (2.76 in), height 130 mm (5.12 in). Comes with 2 auxiliary switches (HQ type) factory-fitted. No undervoltage release, no voltage trip, no trip indicator. If your safety circuit requires a shunt trip or UVR for emergency stop, this variant does not carry it — you would need a different order code in the 3VA1 family. The basic switch variant is 3VA11106EF360AA0 — that is the internal switching mechanism; the -0AC0 suffix adds the auxiliary switches and the specific TM240 release configuration.","metaTitle":"Siemens 3VA1110-6EF36-0AC0 SENTRON MCCB, 100A, 154kA at 415V","metaDescription":"Siemens 3VA1110-6EF36-0AC0 SENTRON molded case circuit breaker, 100A rated at 40°C, 154kA breaking capacity at 415V AC. Active production. Available to order; RFQ for current prici","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"220 kA","at 415 V":"154 kA","at 440 V":"121 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"98 A","at 60 °C":"96 A","at 65 °C":"94 A","at 70 °C":"91 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA11106EF360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM240","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=37853&mlfb=3VA1110-6EF36-0AC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1110-6EF36-0AC0/alternatives.json"},"ai":{"faq":[{"question":"Does 3VA1110-6EF36-0AC0 include a shunt trip or undervoltage release?","answer":"No — this variant has no undervoltage release, no voltage trip, and no trip indicator. It comes with 2 factory-fitted auxiliary switches (HQ type) only."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1110-6EF36-0AC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1110-6EF36-0AC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}