{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1110-6EF36-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1110-6EF36-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1110-6EF36-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1110-6EF36-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1110-6EF36-0DA0, molded case circuit breaker, 3-pole, 100 A rated continuous current at 40 °C, 220 kA breaking capacity at 240 V, TM240 thermal-magnetic release, undervoltage release included.","salesMarkdown":"The Siemens SENTRON 3VA1110-6EF36-0DA0 is a 3-pole molded case circuit breaker rated for line protection, carrying 100 A continuously at 40 °C without derating — and it holds that same 100 A all the way up to 50 °C, which is rare in this frame size. Breaking capacity is where this unit earns its place in high-fault panels: 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and still 17 kA at 690 V. Mechanical endurance rated at 15,000 cycles. ## Footprint and panel fit The breaker measures 76.2 mm wide, 130 mm tall, and 70 mm deep — a compact 3-pole footprint that fits standard Siemens SENTRON mounting plates and busbar systems. No auxiliary contacts are fitted from the factory, and there is no trip indicator or voltage trigger. If you need aux contacts, the integrated auxiliary trip order code is 3VA9608-0BB25 — that is the factory-matched accessory for this release variant.","metaTitle":"Siemens 3VA1110-6EF36-0DA0 SENTRON MCCB, 100 A, 220 kA","metaDescription":"Siemens SENTRON 3VA1110-6EF36-0DA0 molded case circuit breaker, 100 A rated, 220 kA at 240 V. 3-pole line protection with TM240 release. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"220 kA","at 415 V":"154 kA","at 440 V":"121 kA","at 690 V":"17 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"96 A","at 60 °C":"94 A","at 65 °C":"92 A","at 70 °C":"90 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"100 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"TM240","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"100 A","Adjustable response value current / li max.":"1 000 A","Adjustable response value current / li min.":"500 A","Adjustable response value current / lr min.":"70 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=378320&mlfb=3VA1110-6EF36-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1110-6EF36-0DA0/alternatives.json"},"ai":{"faq":[{"question":"Does the 3VA1110-6EF36-0DA0 include an undervoltage release?","answer":"Yes, the undervoltage release (UVR) is built into the base design — it is not an optional accessory on this variant. The design of the auxiliary release is specifically listed as undervoltage release (UVR)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1110-6EF36-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1110-6EF36-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}