{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1110-6EF36-0JC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1110-6EF36-0JC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1110-6EF36-0JC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1110-6EF36-0JC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1110-6EF36-0JC0, molded case circuit breaker, 3-pole, 100 A rated current, breaking capacity 220 kA at 240 VAC, line protection design.","salesMarkdown":"The Siemens SENTRON 3VA1110-6EF36-0JC0 is a 3-pole molded case circuit breaker (MCCB) rated for 100 A continuous current across the 40 °C to 50 °C band, with a slight derating curve starting at 55 °C down to 91 A at 70 °C. Its breaking capacity hits 220 kA at 240 VAC, 154 kA at 415 V, 121 kA at 440 V, and holds at 17 kA up to 690 V — so it handles high-fault utility feeds and transformer secondaries without cascading upstream. This is a line-protection design (not motor-protection), meaning it's sized for cable and busbar protection in distribution panels, not for overload-protecting a motor directly. The breaker measures 130 mm high, 76.2 mm wide, and 70 mm deep — a standard 3-pole MCCB footprint that drops into most SENTRON panelboards and distribution blocks without re-drilling. It's a fixed (non-withdrawable) design, so it's bolted directly to the busbar or mounting plate. Maximum power loss is 25 W, which matters for thermal management in a sealed enclosure — make sure the panel's dissipation rating covers that at full load. The 100 A continuous rating and the 3-pole configuration make it a natural fit for 100 A feeder circuits in commercial or light industrial distribution. No ground-fault monitoring is built in (this variant is 'Without' ground-fault), so if you need GF protection, you'll need an external relay or a different order code from the 3VA11 family.","metaTitle":"Siemens 3VA1110-6EF36-0JC0 SENTRON MCCB, 100 A, 3-Pole, 220","metaDescription":"Siemens SENTRON 3VA1110-6EF36-0JC0 molded case circuit breaker, 100 A rated current, 3-pole, breaking capacity up to 220 kA at 240 VAC. Active production. Sourced to order against","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"220 kA","at 415 V":"154 kA","at 440 V":"121 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"100 A","at 45 °C":"100 A","at 50 °C":"100 A","at 55 °C":"98 A","at 60 °C":"96 A","at 65 °C":"94 A","at 70 °C":"91 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"25 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA11106EF360AA0","Design Of The Auxiliary Switch":"2 auxiliary switches HQ","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM240","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=319677&mlfb=3VA1110-6EF36-0JC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1110-6EF36-0JC0/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 3VA1110-6EF36-0JC0 and how is it quoted for volume purchases?","answer":"We source this part through independent distribution and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here, but a formal quotation for any volume is issued on request."},{"question":"What is 3VA1110-6EF36-0JC0's listed depth (70 mm) on this component line?","answer":"The depth is 70 mm (2.76 in), with a width of 76.2 mm (3 in) and height of 130 mm (5.12 in). These dimensions match the standard SENTRON 3VA fixed-mount MCCB footprint."},{"question":"Will 3VA1110-6EF36-0JC0 drop into a panel that was specified around 3VA1110-5ED36-0AC0 without rewiring?","answer":"The 3VA1110-6EF36-0JC0 shares the same 3-pole, 100 A frame class and the same physical footprint (130 x 76.2 x 70 mm) as the 3VA1110-5ED36-0AC0, so it is mechanically interchangeable in the same panel cutout and busbar spacing. However, the '6EF36' variant carries a shunt trip (STL) auxiliary release, while the '5ED36' variant may have a different release configuration — verify the control wiring for the shunt trip coil voltage and the auxiliary switch wiring before dropping it in."},{"question":"What compliance documentation does this brand provide for 3VA1110-6EF36-0JC0 (RoHS, REACH, UL, IEC)?","answer":"As a Siemens SENTRON MCCB, this part is designed to meet IEC 60947-2 and UL 489 standards for molded case circuit breakers. Compliance declarations (RoHS, REACH) are available from Siemens' documentation portal for the 3VA series. The rated insulation voltage of 800 V and breaking capacities across multiple voltage levels confirm its IEC/UL listing pedigree."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1110-6EF36-0JC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1110-6EF36-0JC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}