{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1112-4ED16-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1112-4ED16-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1112-4ED16-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1112-4ED16-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1112-4ED16-0AA0, molded case circuit breaker, 1-pole, 125 A (40 °C), TM210 trip, 75.6 kA at 240 V AC, 70 mm depth, IP40 front.","salesMarkdown":"## Siemens SENTRON 3VA1112-4ED16-0AA0 — 125 A, 1-Pole MCCB with TM210 Trip The interrupting rating reaches 75.6 kA at 240 V AC and 9 kA at 415 V AC, which covers most commercial and light industrial fault-current scenarios. At 415 V AC the rating drops to 9 kA, still adequate for typical 400 V distribution in smaller subpanels. The TM210 trip is a fixed thermal-magnetic design — no dials or interchangeable rating plugs. The thermal element tracks the 125 A frame through the ambient derating curve: it holds 125 A steady from 40 °C to 50 °C, then tapers to 122 A at 55 °C, 120 A at 60 °C, 117 A at 65 °C, and 114 A at 70 °C. The 3VA1112-4ED16-0AA0 snaps onto standard DIN rail. Its width is 25.4 mm (1 in) — exactly one module — and depth is 70 mm (2.76 in) from the rail to the front face. Height is 130 mm (5.12 in). That single-module width is the key dimension for retrofit: it occupies the same slot as a 1-pole miniature breaker, so it drops into existing DIN-rail subpanels without widening the enclosure or re-spacing adjacent devices. ## Electrical Ratings and Operating Range Operating voltage is 415 V AC and 125 V DC.","metaTitle":"Siemens 3VA1112-4ED16-0AA0 SENTRON MCCB, 1-Pole, 125 A, 75.6","metaDescription":"Siemens SENTRON 3VA1112-4ED16-0AA0 molded case circuit breaker, 1-pole, 125 A rated at 40 °C, 75.6 kA interrupting at 240 V AC. TM210 thermal-magnetic trip. Active production, quot","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"25.4 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"75.6 kA","at 415 V":"9 kA","at 40 °C":"125 A","at 45 °C":"125 A","at 50 °C":"125 A","at 55 °C":"122 A","at 60 °C":"120 A","at 65 °C":"117 A","at 70 °C":"114 A","Depth [In]":"2.76 in","Width [In]":"1 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"1","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"9.37 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"500 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"415 V","operating voltage / at DC / rated value":"125 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"S","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e80eb231daa657ec5ae8cac91ff2dbc8.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=496196&mlfb=3VA1112-4ED16-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1112-4ED16-0AA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1112-4ED16-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1112-4ED16-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}