{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1112-6MH32-0CC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1112-6MH32-0CC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1112-6MH32-0CC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1112-6MH32-0CC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 160, breaking capacity class H, Icu=70kA @ 415V, 3-pole, starter protection TM120M, AM, In=125A, without overload protection, short-circuit protection Ii=5…15 x In, nut keeper kit, undervoltage release 120-127V AC 50/60Hz, 2 auxiliary switches HQ.","salesMarkdown":"The Siemens 3VA1112-6MH32-0CC0 is a 3-pole IEC frame 160 MCCB rated at 125 A with a class H breaking capacity of 70 kA at 415 V. The TM120M trip unit provides starter protection: thermal-magnetic with a fixed thermal element rated 125 A and an adjustable magnetic short-circuit pickup from 5 to 15 times In (625 A to 1875 A). Note the description explicitly states \"without overload protection\" — this breaker is configured for short-circuit protection only; overload coordination relies on an external overload relay or motor starter. Two HQ auxiliary switches are built in, providing status feedback for the open/closed position.","metaTitle":"Siemens 3VA1112-6MH32-0CC0 Circuit Breaker, 70kA @ 415V, 125","metaDescription":"Siemens 3VA1112-6MH32-0CC0 IEC frame 160 MCCB, 70kA breaking capacity at 415V, 3-pole, 125A, with undervoltage release and aux switches. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=280799&mlfb=3VA1112-6MH32-0CC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1112-6MH32-0CC0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA1112-6MH32-0CC0?","answer":"The breaking capacity is Icu = 70 kA at 415 V (class H), which is suitable for high-fault industrial installations."},{"question":"How do I get pricing and availability for 3VA1112-6MH32-0CC0?","answer":"Pricing and availability are confirmed at quote time. Submit an RFQ through this listing; the part is sourced to order through independent distribution channels."},{"question":"Does 3VA1112-6MH32-0CC0 include overload protection?","answer":"No. The description states 'without overload protection' — this breaker provides only short-circuit protection. An external overload relay or motor starter is required for overload coordination."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1112-6MH32-0CC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1112-6MH32-0CC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}