{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1112-6MH36-0KH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1112-6MH36-0KH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1112-6MH36-0KH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1112-6MH36-0KH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 series, IEC frame 160, breaking capacity class H, Icu=70kA @ 415V, 3-pole, 125A TM120M thermal-magnetic trip, shunt trip, 2 aux switches + 1 alarm switch, clamp terminals.","salesMarkdown":"The Siemens 3VA1112-6MH36-0KH0 is a 3-pole molded case circuit breaker on the IEC frame 160 platform, rated In=125A with a TM120M thermal-magnetic trip unit. This is not the standard 'N' or 'S' class; The trip is configured for starter protection (TM120M, AM) with short-circuit pickup Ii adjustable from 5 to 15 times In (625 A to 1875 A). Note the description explicitly states 'without overload protection' — the TM120M provides the thermal element, but the listing flags no overload protection, so verify whether your motor starter or soft starter handles the overload function separately. The shunt trip (STL) operates on 220-250 V DC or 208-277 V AC, letting you remotely trip the breaker from a safety relay or E-stop circuit. ## Auxiliary and alarm switching The aux switches signal the breaker's open/closed position to a PLC or status lamp; the alarm switch changes state only when the breaker trips on a fault, not on a manual open. That distinction matters for remote fault diagnostics — the alarm contact tells you the breaker didn't just get turned off, it cleared a fault. ## Termination and panel fit Clamp-type terminals accept copper or aluminum conductors without lug kits for most panel applications. Verify the shunt trip voltage matches your control voltage before wiring; the STL coil draws continuous power when energized, so factor that into your 24 V DC supply budget if stepping down from the listed 220-250 V DC range.","metaTitle":"Siemens 3VA1112-6MH36-0KH0 Circuit Breaker, 70kA @ 415V, 125","metaDescription":"Siemens 3VA1112-6MH36-0KH0 IEC frame 160 circuit breaker, breaking capacity class H, Icu=70kA @ 415V, 3-pole, 125A TM trip, shunt trip, aux switches. Current lifecycle stage. Quote","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=176406&mlfb=3VA1112-6MH36-0KH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1112-6MH36-0KH0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this breaker?","answer":"Icu=70kA at 415 V AC, breaking capacity class H on the IEC frame 160 platform."},{"question":"Where can I buy 3VA1112-6MH36-0KH0 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What does the shunt trip voltage range cover?","answer":"The shunt trip (STL) operates on 220-250 V DC or 208-277 V AC."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1112-6MH36-0KH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1112-6MH36-0KH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}