{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-3ED16-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-3ED16-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-3ED16-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-3ED16-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1116-3ED16-0AA0, 1-pole molded case circuit breaker, 160 A rated, TM210 thermal-magnetic trip, 52.5 kA interrupting at 240 V AC.","salesMarkdown":"## 160 A continuous, single-pole — the interrupting capacity that matters The Siemens 3VA1116-3ED16-0AA0 is a 1-pole SENTRON molded case circuit breaker rated 160 A continuous at 40 °C through 50 °C — no derating needed until ambient hits 55 °C, where it steps to 158 A. That 160 A hold across a 10 °C band means it handles a warm panel without tripping early. Interrupting capacity is 52.5 kA at 240 V AC and 7.5 kA at 415 V AC — the 240 V figure covers most North American panelboard fault duties, while the 415 V number tells you it's not a high-fault device for 400 V industrial mains. Match it to a service with available fault current below that ceiling. ## TM210 trip, line protection, and the 1-inch slot The TM210 thermal-magnetic trip unit is fixed — no interchangeable trip blocks, no ground-fault module, no communication. It's a straight line-protection breaker for feeder or branch circuits where you need thermal overload and magnetic short-circuit response only. Physical footprint is 130 mm high, 25.4 mm wide, 70 mm deep — that 25.4 mm (1 inch) width per pole is the standard MCCB module. ## Current production — sourcing this BOM line Submit an RFQ for your BOM quantity.","metaTitle":"Siemens 3VA1116-3ED16-0AA0 MCCB, 160A, 52.5kA at 240V","metaDescription":"Siemens SENTRON 3VA1116-3ED16-0AA0 molded case circuit breaker, 160A rated, 1-pole, TM210 trip. Interrupting capacity 52.5kA at 240V AC.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"25.4 mm","title":"3VA1116-3ED16-0AA0","Height":"130 mm","at 240 V":"52.5 kA","at 415 V":"7.5 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"158 A","at 60 °C":"155 A","at 65 °C":"153 A","at 70 °C":"150 A","Depth [In]":"2.76 in","Width [In]":"1 in","Height [In]":"5.12 in","description":"circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 240V 1-pole, line protection TM210, FTFM, In=160A overload protection Ir=160A fixed short-circuit protection Ii=10 x In clamp connection","Trip Indicator":"No","Number Of Poles":"1","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12.67 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"500 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","operating voltage / at AC / rated value":"415 V","Max. rated operational voltage Ue with DC":"125 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"N","Mechanical Service Life (Switching Cycles) / Typical":"20 000","reference value setting current (Ii) / for I-tripping":"x In","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","type of value list setting current (Ii) / for I-tripping":"Fest","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1,5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$422.49 – $435.55","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9a2dffe2356ce1e18567e37526752182.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=348183&mlfb=3VA1116-3ED16-0AA0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-3ED16-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-3ED16-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}