{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-3ED46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-3ED46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-3ED46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-3ED46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1116-3ED46-0AA0, 4-pole molded case circuit breaker, 160 A at 40 °C, TM210 thermal-magnetic trip unit, interrupting capacity 75.6 kA at 240 V AC, 70 mm depth.","salesMarkdown":"The TM210 thermal-magnetic trip unit provides fixed thermal and magnetic settings — no field adjustment, which simplifies specification but means the breaker must be selected for the exact load profile. Interrupting capacity runs 75.6 kA at 240 V, 52.5 kA at 415 V, and 11.9 kA at 690 V, giving solid fault-clearing headroom across common low-voltage networks. Above 50 °C the curve steps down: 158 A at 55 °C, 155 A at 60 °C, 153 A at 65 °C, and 150 A at 70 °C. Interrupting capacity drops with system voltage as expected. At 415 V (common 3-phase distribution in Europe and Asia) the breaker clears 52.5 kA symmetrically. The 4-pole width (101.6 mm) is standard for this frame size; verify the existing panel cutout and busbar spacing if retrofitting into an enclosure originally wired for a different MCCB family.","metaTitle":"Siemens 3VA1116-3ED46-0AA0 SENTRON MCCB, 4P, 160A, TM210, 70","metaDescription":"Siemens SENTRON 3VA1116-3ED46-0AA0 molded case circuit breaker, 4-pole, 160A at 40°C, TM210 trip unit, interrupting capacity 75.6kA at 240V. Active production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"101.6 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 500 V":"11.9 kA","at 690 V":"11.9 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"158 A","at 60 °C":"155 A","at 65 °C":"153 A","at 70 °C":"150 A","Depth [In]":"2.76 in","Width [In]":"4 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"4","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"38 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","design of the N-conductor protection":"without","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"600 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"N","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a9ef9339803208d6b673b9f9a51064fb.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=316178&mlfb=3VA1116-3ED46-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1116-3ED46-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What type of trip unit does the 3VA1116-3ED46-0AA0 use?","answer":"A TM210 thermal-magnetic trip unit with fixed settings — no field adjustment. It is designed for line protection, not motor or generator protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-3ED46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-3ED46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}