{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-3EF36-0AG0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-3EF36-0AG0","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-3EF36-0AG0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-3EF36-0AG0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1116-3EF36-0AG0, molded case circuit breaker, 3-pole, 160 A, TM240 thermal-magnetic release, 75.6 kA at 240 V, line protection design, 70 mm depth, 76.2 mm width, 130 mm height.","salesMarkdown":"It's a 3-pole unit rated 160 A continuous at 40 °C with a TM240 thermal-magnetic overcurrent release — meaning the thermal pickup is fixed at 160 A, and the magnetic instantaneous trip is adjustable around 240 A. The interrupting capacity hits 75.6 kA at 240 V, 52.5 kA at 415 V, and 32 kA at 440 V, dropping to 11.9 kA at 500 V and 690 V. At 55 °C it's 158 A, at 60 °C it's 155 A, at 65 °C it's 153 A, and at 70 °C it's 150 A. Maximum power loss is 38 W — that's the heat this breaker dumps into the enclosure, so factor it into the thermal budget if you're stacking several in a tight cabinet. The trip indicator gives a visual flag when the breaker has tripped on overcurrent — useful for a quick panel walk-down without opening doors. The auxiliary switch configuration is 1 auxiliary switch + 1 trip alarm switch HP, so you get both a status signal and a separate alarm on trip. Designed for line protection, so it's the main or feeder breaker, not a motor-protective device.","metaTitle":"Siemens 3VA1116-3EF36-0AG0 SENTRON MCCB, 160A, 3-Pole, 75.6k","metaDescription":"Siemens SENTRON 3VA1116-3EF36-0AG0 molded case circuit breaker, 160A, 3-pole, TM240 release, 75.6 kA at 240 V. Current lifecycle. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 500 V":"11.9 kA","at 690 V":"11.9 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"158 A","at 60 °C":"155 A","at 65 °C":"153 A","at 70 °C":"150 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"Yes","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"38 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA11163EF360AA0","Design Of The Auxiliary Switch":"1 auxiliary switch + 1 trip alarm switch HP","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM240","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"2","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB11","Switching Capacity Class Of The Circuit Breaker":"N","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=253202&mlfb=3VA1116-3EF36-0AG0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1116-3EF36-0AG0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1116-3EF36-0AG0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Send the order code and quantity for current pricing and availability confirmation at quote time."},{"question":"What is 3VA1116-3EF36-0AG0's interrupting capacity at 415 V?","answer":"The interrupting capacity at 415 V is 52.5 kA. At 240 V it's 75.6 kA, at 440 V it's 32 kA, and at 500 V / 690 V it's 11.9 kA."},{"question":"What compliance documentation does this brand provide for 3VA1116-3EF36-0AG0?","answer":"As a Siemens SENTRON MCCB, standard compliance documentation includes the manufacturer's declaration of conformity to IEC/EN 60947-2, UL 489 listing, and RoHS/REACH compliance statements available through the Siemens Industry Online Support portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-3EF36-0AG0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-3EF36-0AG0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}