{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-5ED32-0AE0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-5ED32-0AE0","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-5ED32-0AE0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-5ED32-0AE0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1116-5ED32-0AE0, molded case circuit breaker, 3-pole, 160 A rated continuous current Iu, TM210 thermal-magnetic release, line protection version, interrupting rating 187 kA at 240 V.","salesMarkdown":"It's built for line protection — think main feeder or large subfeed in a distribution panel where you need a solid interrupting rating without communication or ground-fault add-ons. The interrupting ratings are what make this part stand out: 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V. At 415 V it still handles 121 kA, which covers most industrial low-voltage distribution. It's a straightforward overcurrent protector: thermal for overload, magnetic for short-circuit. The auxiliary contact version is 4 HQ switches, so you get status feedback without needing a separate contactor block. Above that it starts to step down: 153.6 A at 55 °C, 150.4 A at 60 °C, 147.2 A at 65 °C, and 144 A at 70 °C. That 76.2 mm width is three 25.4 mm pole spaces — standard for a 3-pole MCCB this size. Depth of 70 mm means it'll clear most backpanel wiring gutters without sticking out past the gland plate.","metaTitle":"Siemens 3VA1116-5ED32-0AE0 SENTRON MCCB, 160 A, 187 kA at 24","metaDescription":"Siemens SENTRON 3VA1116-5ED32-0AE0 molded case circuit breaker, 160 A rated, 187 kA interrupting at 240 V. TM210 release, 3-pole, IP40 front. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"75.6 kA","at 690 V":"17 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"153.6 A","at 60 °C":"150.4 A","at 65 °C":"147.2 A","at 70 °C":"144 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"4 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"160 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"without auxiliaryrelease","Ground fault monitoring version":"Without","Design of the overcurrent release":"TM210","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"160 A","Adjustable response value current / li max.":"1 600 A","Adjustable response value current / li min.":"1 600 A","Adjustable response value current / lr min.":"160 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"4","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=171603&mlfb=3VA1116-5ED32-0AE0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1116-5ED32-0AE0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting rating of 3VA1116-5ED32-0AE0 at 240 V?","answer":"187 kA at 240 V. It also carries 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V."},{"question":"What does the TM210 release mean on this MCCB?","answer":"TM210 is a fixed thermal-magnetic overcurrent release — thermal element for overload protection, magnetic element for short-circuit. No electronic adjustment or communication."},{"question":"Where can I buy 3VA1116-5ED32-0AE0 and how is it quoted?","answer":"Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here."},{"question":"Will 3VA1116-5ED32-0AE0 fit in a panel designed for 3VA1110-5EE32-0DC0?","answer":"Both are 3-pole SENTRON MCCBs with the same 76.2 mm width per pole, so the footprint is identical. The main difference is the continuous current rating — 160 A on this unit versus the lower-rated peer — so check the load before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-5ED32-0AE0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-5ED32-0AE0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}