{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-5ED42-0AA0-ZD00","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-5ED42-0AA0-ZD00","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-5ED42-0AA0-ZD00","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-5ED42-0AA0-ZD00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 160, breaking capacity class M, Icu=55kA @ 415V, 4-pole, line protection TM210, FTFM, In=160A, Ir=160A fixed, Ii=10 x In, N conductor unprotected, nut keeper kit for DC Power OEM in China.","salesMarkdown":"The Siemens 3VA1116-5ED42-0AA0-ZD00 is a 4-pole IEC frame 160 molded case circuit breaker from the 3VA1 series, configured for line protection with a fixed thermal-magnetic trip (TM210, FTFM). That class M rating puts it in the middle of the 3VA1 breaking capacity range, suitable for industrial distribution panels where fault currents are high but not extreme. The continuous current rating is In=160A with overload protection fixed at Ir=160A and short-circuit pickup fixed at Ii=10 x In (1600 A instantaneous). This variant includes a nut keeper kit and is specified for DC Power OEM applications in China. The 4-pole configuration (3 phases + unprotected neutral) is common in three-phase distribution boards feeding downstream sub-distribution or directly powering equipment. The fixed thermal-magnetic trip means no adjustment dials — set it and forget it, which suits OEM builds where the load is known and consistent. The nut keeper kit simplifies panel wiring by retaining hardware during assembly.","metaTitle":"Siemens 3VA1116-5ED42-0AA0-ZD00 Circuit Breaker, 160A, 55kA","metaDescription":"Siemens 3VA1116-5ED42-0AA0-ZD00 IEC frame 160 breaker, 55kA breaking capacity @ 415V, 160A fixed thermal-magnetic, current lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1667598&mlfb=3VA1116-5ED42-0AA0-ZD00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1116-5ED42-0AA0-ZD00/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 3VA1116-5ED42-0AA0-ZD00 and how is it quoted for volume?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time; volume pricing is negotiable depending on quantity and lead time."},{"question":"What are the key ratings of this breaker?","answer":"Icu=55kA at 415 V, In=160A, Ir=160A fixed overload, Ii=10 x In (1600 A) fixed short-circuit pickup, 4-pole with unprotected neutral, TM210 thermal-magnetic trip."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-5ED42-0AA0-ZD00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-5ED42-0AA0-ZD00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}