{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-5EE32-0JC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-5EE32-0JC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-5EE32-0JC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-5EE32-0JC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1116-5EE32-0JC0, Molded case circuit breaker, 3-pole, 160 A, TM220 thermal-magnetic release, line protection, 187 kA interrupting at 240 V.","salesMarkdown":"## What the interrupting ratings mean for your fault-current study The interrupting capacity scales with system voltage: 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V. The 690 V rating (17 kA) is the limiting case; if your system runs at 690 V, verify the SCCR at that point against your transformer nameplate. ## Thermal derating — the 160 A frame doesn't hold 160 A everywhere Above 50 °C the TM220 thermal-magnetic release begins to derate: 153.6 A at 55 °C, 150.4 A at 60 °C, 147.2 A at 65 °C, and 144 A at 70 °C. ## Auxiliary and shunt trip — wired for remote tripping, no comms The auxiliary switches give status feedback (open/closed/tripped) to a PLC or annunciator. If you need remote monitoring beyond dry contacts, this is not the version; the frame accepts the 3VA9688-0BL32 integrated auxiliary trip module, but that adds a trip coil, not a fieldbus gateway. ## Panel fit — dimensions and IP40 front Width 76.2 mm, height 130 mm, depth 70 mm. The 3-pole frame mounts into a standard MCCB cutout or DIN-rail adapter (not included). The front is clean: no trip indicator, no LCD, just the handle and the TM220 rating plug.","metaTitle":"Siemens 3VA1116-5EE32-0JC0 SENTRON MCCB, 160 A, 3-Pole, TM22","metaDescription":"Siemens 3VA1116-5EE32-0JC0 SENTRON molded case circuit breaker, 160 A rated current, 3-pole, TM220 release, 187 kA at 240 V. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"75.6 kA","at 690 V":"17 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"153.6 A","at 60 °C":"150.4 A","at 65 °C":"147.2 A","at 70 °C":"144 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"160 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL32","Design of the overcurrent release":"TM220","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"160 A","Adjustable response value current / li max.":"1 600 A","Adjustable response value current / li min.":"1 600 A","Adjustable response value current / lr min.":"112 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=148103&mlfb=3VA1116-5EE32-0JC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1116-5EE32-0JC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1116-5EE32-0JC0 and how is it quoted?","answer":"This part is sourced and quoted to order through independent distribution against an RFQ. Availability and current pricing are confirmed at quote time — no stock or price figures are published here."},{"question":"What is the closest functional second-source to 3VA1116-5EE32-0JC0?","answer":"The 3VA1010-2ED32-0JA0 is a lower-current sibling in the same 3VA platform. It will not drop into the same cutout without checking the frame size — the 3VA1116 uses a 160 A frame; the 3VA1010 uses a 100 A frame. Panel cutout dimensions differ, so verify the mounting footprint before substituting."},{"question":"What compliance documentation does Siemens provide for 3VA1116-5EE32-0JC0?","answer":"The SENTRON 3VA series carries CE marking for the European market and is designed to meet IEC 60947-2. UL and CSA listings are standard on most 3VA variants; confirm the specific file number for this order code at quote time. RoHS and REACH declarations are available from Siemens support."},{"question":"Will 3VA1116-5EE32-0JC0 drop into a panel specified around 3VA1010-2ED32-0JA0 without rewiring?","answer":"Not without checking the mounting. The 3VA1116 frame is physically larger (160 A frame vs 100 A frame) — the width, height, and depth differ. The busbar spacing and lug positions may not align. Pull the panel cutout dimensions for both before assuming a direct swap."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-5EE32-0JC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-5EE32-0JC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}