{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-5EF36-0JH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-5EF36-0JH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-5EF36-0JH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-5EF36-0JH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1116-5EF36-0JH0, Molded case circuit breaker, 3-pole, 160 A, line protection, TM240 overcurrent release, shunt trip STL, 2 aux + 1 alarm, 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, 17 kA at 690 V.","salesMarkdown":"## Siemens 3VA1116-5EF36-0JH0 — 160 A MCCB with TM240 Release and Shunt Trip The interrupting capacity reaches 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V — figures that define its fault-clearing capability at each voltage level and directly govern selectivity coordination with downstream devices. The auxiliary trip accessory is order code 3VA9688-0BL32. The breaker is rated for 15,000 mechanical/electrical endurance cycles. Dimensions are 130 mm height, 76.2 mm width, and 70 mm depth — a standard 3-pole MCCB footprint for panel mounting. ## Current Rating vs. Ambient Temperature Above that, the continuous current derates: 153.6 A at 55 °C, 150.4 A at 60 °C, 147.2 A at 65 °C, and 144 A at 70 °C. For a panel running warm, the actual load limit is the derated value at the enclosure's internal ambient — not the 160 A nameplate.","metaTitle":"Siemens 3VA1116-5EF36-0JH0 SENTRON MCCB, 160 A, 3-Pole, 187","metaDescription":"Siemens SENTRON 3VA1116-5EF36-0JH0 molded case circuit breaker, 160 A, 3-pole, line protection. Rated 187 kA at 240 V, 121 kA at 415 V. IP40 front. Active production. Sourced to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"75.6 kA","at 690 V":"17 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"153.6 A","at 60 °C":"150.4 A","at 65 °C":"147.2 A","at 70 °C":"144 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"160 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL32","Design of the overcurrent release":"TM240","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"160 A","Adjustable response value current / li max.":"1 600 A","Adjustable response value current / li min.":"800 A","Adjustable response value current / lr min.":"112 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=160677&mlfb=3VA1116-5EF36-0JH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1116-5EF36-0JH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1116-5EF36-0JH0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer."},{"question":"What is 3VA1116-5EF36-0JH0's listed depth and width?","answer":"The depth is 70 mm and the width is 76.2 mm, with a height of 130 mm — a standard 3-pole MCCB footprint for panel mounting."},{"question":"What compliance documentation does this brand provide for 3VA1116-5EF36-0JH0?","answer":"The breaker is designed to reference code Q per DIN EN 81346-2. Siemens typically provides RoHS, REACH, UL, and IEC declarations for SENTRON MCCBs; specific certificates are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-5EF36-0JH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-5EF36-0JH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}