{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-5EF46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-5EF46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-5EF46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-5EF46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1116-5EF46-0AA0, 4-pole molded case circuit breaker, 160 A at 40 °C, TM240 thermal-magnetic trip, 187 kA breaking capacity at 240 V.","salesMarkdown":"## SENTRON 3VA1116-5EF46-0AA0 — 4-Pole MCCB for Line Protection Breaking capacity is specified across multiple voltage levels: 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at both 500 V and 690 V. This range makes the breaker suitable for high-fault-current installations where selectivity with upstream devices is required. Above that, derating applies: 158 A at 55 °C, 155 A at 60 °C, 153 A at 65 °C, and 150 A at 70 °C. Maximum power loss is 38 W, which contributes to enclosure heat load. Include this figure in thermal calculations for sealed cabinets. This MCCB has no communication function, no undervoltage release, no voltage trigger, no trip indicator, and no ground-fault monitoring. It is a base-line protection device — specify add-on modules or a different variant if those features are required. As a Siemens SENTRON product, the 3VA1116-5EF46-0AA0 is designed to meet IEC 60947-2 and relevant UL/CSA standards for molded case circuit breakers. Compliance documentation including RoHS and REACH declarations is available from Siemens upon request. For audit purposes, the manufacturer provides a declaration of conformity and test certificates traceable to the order code.","metaTitle":"Siemens 3VA1116-5EF46-0AA0 SENTRON MCCB, 4-Pole, 160 A, TM24","metaDescription":"Siemens SENTRON 3VA1116-5EF46-0AA0 molded case circuit breaker, 4-pole, 160 A at 40 °C, TM240 trip unit, 187 kA at 240 V. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"101.6 mm","Height":"130 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"75.6 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"158 A","at 60 °C":"155 A","at 65 °C":"153 A","at 70 °C":"150 A","Depth [In]":"2.76 in","Width [In]":"4 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"4","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"38 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","design of I-trip / adjustable":"Yes","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM240","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","design of the N-conductor protection":"without","operating voltage / at AC / rated value":"690 V","Max. rated operational voltage Ue with DC":"600 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","let-through energy characteristic / at 240 V":"DE_3VA1_0u1_160A_TM_line u starter_3u4p_240V","let-through energy characteristic / at 415 V":"DE_3VA1_0u1_160A_TM_line u starter_3u4p_415V","let-through energy characteristic / at 690 V":"DE_3VA1_0u1_160A_TM_line u starter_3u4p_690V","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","set values setting current (Ii) / for I-tripping":"5;6;7;8;9;10","Mechanical Service Life (Switching Cycles) / Typical":"20 000","Tripping Characteristic / Of The Lower Tolerance Band":"AK_3VA1_1_160A_TM2_NuSuMuH_uT","Tripping Characteristic / Of The Upper Tolerance Band":"AK_3VA1_1_160A_TM2_NuSuMuH_oT","reference value setting current (Ii) / for I-tripping":"x In","reference value setting current (InN) / for N-tripping":"x In","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","type of value list setting current (Ii) / for I-tripping":"St","type of value list setting current (InN) / for N-tripping":"St","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1,5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=153079&mlfb=3VA1116-5EF46-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1116-5EF46-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Does 3VA1116-5EF46-0AA0 include ground-fault monitoring?","answer":"No, this variant is supplied without ground-fault monitoring. It is a base-line line-protection MCCB with no communication function, undervoltage release, or trip indicator."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-5EF46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-5EF46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}