{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-6ED42-0AA0-ZD00","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-6ED42-0AA0-ZD00","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-6ED42-0AA0-ZD00","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-6ED42-0AA0-ZD00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 160, 4-pole circuit breaker, 70kA Icu @ 415V, TM210 line protection, In=160A fixed overload Ir=160A, fixed short-circuit Ii=10 x In, N conductor unprotected, nut keeper kit for DC Power OEM in China.","salesMarkdown":"The Siemens 3VA1116-6ED42-0AA0-ZD00 is a 4-pole IEC frame 160 circuit breaker with a 70 kA Icu at 415 V — that's the breaking capacity class H rating, meaning it safely clears faults up to 70 kA without failing catastrophically, which is the figure you need for selectivity studies in a 415 V distribution panel. The TM210 trip unit gives fixed thermal-magnetic protection: overload Ir is fixed at 160 A (the breaker's full frame rating), and short-circuit pickup Ii is fixed at 10 x In, or 1600 A. That's a relatively high magnetic pickup — suitable for feeder circuits feeding motor loads or transformers where inrush won't nuisance-trip, but check coordination with downstream devices that may have lower let-through. The description flags it as a DC Power OEM variant for China — the nut keeper kit is a mechanical accessory to prevent terminal loosening under vibration, common in OEM builds. ## Integration notes Mounts on DIN rail in a standard distribution panel. The 4-pole form factor occupies four modular units — verify panel fill factor and thermal derating if the breaker is enclosed in a non-ventilated cabinet. The nut keeper kit is pre-installed; no additional hardware needed for the line and load terminals. The TM210 trip unit is non-interchangeable — what you see is what you get on Ir and Ii settings.","metaTitle":"Siemens 3VA1116-6ED42-0AA0-ZD00 160A Circuit Breaker, 70kA @","metaDescription":"Siemens 3VA1116-6ED42-0AA0-ZD00 160A IEC frame 160 circuit breaker, 70kA Icu @ 415V, 4-pole, TM210. Lifecycle stage is current. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5c7618a239113c45ef37afba0be4bb0c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1667607&mlfb=3VA1116-6ED42-0AA0-ZD00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1116-6ED42-0AA0-ZD00/alternatives.json"},"ai":{"faq":[{"question":"How do I get pricing and availability for 3VA1116-6ED42-0AA0-ZD00?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels."},{"question":"What is the breaking capacity of this breaker?","answer":"The breaking capacity is 70 kA Icu at 415 V, which is class H in the 3VA1 frame."},{"question":"What does the TM210 trip unit mean?","answer":"TM210 means thermal-magnetic protection with fixed overload Ir at 160 A and fixed short-circuit pickup Ii at 10 x In (1600 A)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-6ED42-0AA0-ZD00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-6ED42-0AA0-ZD00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}