{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-6ED46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-6ED46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-6ED46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-6ED46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1116-6ED46-0AA0, molded case circuit breaker, 4-pole, 160 A at 40 °C, TM210 thermal-magnetic release, breaking capacity 220 kA at 240 V, IP40 front, line protection design.","salesMarkdown":"## What this MCCB delivers The Siemens 3VA1116-6ED46-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated 160 A at 40 °C, with 4 poles and a TM210 thermal-magnetic overcurrent release. The breaking capacity is 220 kA at 240 V, 154 kA at 415 V, and 75.6 kA at 440 V, so it handles high-fault utility feeds without cascading upstream. The TM210 release gives a fixed thermal curve and magnetic trip, no electronic adjustment. Front protection is IP40 — suitable for dry indoor panels; not rated for washdown. Width is 101.6 mm (4 in), depth 70 mm (2.76 in), height 130 mm (5.12 in). Verify the gland plate cutout matches the 101.6 mm width before drilling. ## Current derating and thermal limits Above that, derating is gradual: 158 A at 55 °C, 155 A at 60 °C, 153 A at 65 °C, and 150 A at 70 °C.","metaTitle":"Siemens 3VA1116-6ED46-0AA0 SENTRON MCCB, 160A, 4-Pole, 220kA","metaDescription":"Siemens 3VA1116-6ED46-0AA0 SENTRON molded case circuit breaker, 160A rated at 40°C, 4-pole, TM210 release, breaking capacity 220kA at 240V. Current production. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"101.6 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"220 kA","at 415 V":"154 kA","at 440 V":"75.6 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"158 A","at 60 °C":"155 A","at 65 °C":"153 A","at 70 °C":"150 A","Depth [In]":"2.76 in","Width [In]":"4 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"4","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"38 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","design of the N-conductor protection":"without","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"600 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5611070d5e4c6fd41c67ca61a012c57b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=149199&mlfb=3VA1116-6ED46-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1116-6ED46-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1116-6ED46-0AA0 and how do I get a price?","answer":"We source this part to order against an RFQ. Submit a quote request through the storefront; availability and current pricing are confirmed at quote time."},{"question":"What is 3VA1116-6ED46-0AA0's listed depth?","answer":"The depth is 70 mm (2.76 in)."},{"question":"What is 3VA1116-6ED46-0AA0's listed width?","answer":"The width is 101.6 mm (4 in)."},{"question":"Will 3VA1116-6ED46-0AA0 drop into a panel that was specified around 3VA1112-5EE32-0AA0 without rewiring?","answer":"Mechanically yes — both are 4-pole SENTRON 3VA breakers with the same 101.6 mm width and 70 mm depth, so the mounting holes and busbar positions align. However, the 3VA1116-6ED46-0AA0 is rated 160 A with a TM210 release, while the 3VA1112-5EE32-0AA0 is a different current rating and trip curve. Verify the load and protection coordination before swapping; the wiring lugs accept the same conductor sizes."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-6ED46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-6ED46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}