{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-6EE32-0AC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-6EE32-0AC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-6EE32-0AC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-6EE32-0AC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1116-6EE32-0AC0, molded case circuit breaker, line protection, 3-pole, 25 A rated continuous current Iu, TM220 thermal-magnetic overcurrent release, 187 kA breaking capacity at 240 V AC.","salesMarkdown":"It carries a 187 kA breaking capacity at 240 V, dropping to 121 kA at 415 V, 76 kA at 440 V, and 17 kA at both 500 V and 690 V — numbers that matter when you're coordinating with downstream gear and need to know it won't let a fault cascade upstream. At 40 °C, 45 °C, and 50 °C it holds the full 25 A; at 55 °C and 60 °C it derates to 24 A, and at 65 °C and 70 °C it drops to 23 A. That derating curve means you don't lose headroom until you're past 50 °C — common in a sealed panel but worth checking if your enclosure runs hot. The 130 mm height and 3-inch width (76.2 mm) fit the standard SENTRON 3VA footprint, so it'll drop into an existing panel layout without re-drilling the mounting plate.","metaTitle":"Siemens 3VA1116-6EE32-0AC0 SENTRON MCCB, 25 A, 187 kA at 240","metaDescription":"Siemens SENTRON 3VA1116-6EE32-0AC0 molded case circuit breaker, 25 A rated, TM220 release, 187 kA at 240 V. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Height":"130 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"76 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"25 A","at 45 °C":"25 A","at 50 °C":"25 A","at 55 °C":"24 A","at 60 °C":"24 A","at 65 °C":"23 A","at 70 °C":"23 A","Width [in]":"3 in","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"25 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"without auxiliaryrelease","Ground fault monitoring version":"Without","Design of the overcurrent release":"TM220","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"25 A","Adjustable response value current / li max.":"320 A","Adjustable response value current / li min.":"320 A","Adjustable response value current / lr min.":"18 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/79dd7ed625ac853e7d79299b0c693f2e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=913313&mlfb=3VA1116-6EE32-0AC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1116-6EE32-0AC0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1116-6EE32-0AC0 and how is it quoted?","answer":"We source this part to order against an RFQ through independent distribution. Submit a request for quote and we'll confirm availability and current pricing — no stock count, no lead-time number here, but we'll get you a real answer fast."},{"question":"What's the breaking capacity of 3VA1116-6EE32-0AC0 at different voltages?","answer":"187 kA at 240 V, 121 kA at 415 V, 76 kA at 440 V, and 17 kA at both 500 V and 690 V. That's enough for most industrial service-entrance or feeder applications, but check your available fault current — if you're above 17 kA at 690 V, this breaker won't clear it."},{"question":"Will 3VA1116-6EE32-0AC0 drop into a panel designed for 3VA1110-5EE32-0JA0?","answer":"Both are 3-pole SENTRON 3VA breakers with the same 130 mm height and 3-inch width, so the physical footprint and mounting hole pattern are identical. The difference is in the release and ratings: the 3VA1116-6EE32-0AC0 carries a 25 A TM220 release and higher breaking capacities (187 kA vs lower on the 3VA1110 variant). Electrically it's a drop-in if the bus bar and lug ratings match."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-6EE32-0AC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-6EE32-0AC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}