{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-6EE32-0DA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-6EE32-0DA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-6EE32-0DA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-6EE32-0DA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1116-6EE32-0DA0, molded case circuit breaker, 3-pole, TM220 thermal-magnetic release, 160 A at 40 °C, line protection version.","salesMarkdown":"The breaking capacity is 220 kA at 240 V AC, 154 kA at 415 V, 75.6 kA at 440 V, and 17 kA at both 500 V and 690 V — so the interrupting rating depends heavily on the system voltage you are working with. At 690 V, 17 kA is still a strong figure for an MCCB of this frame size, but it is not the 220 kA you get at 240 V; selectivity studies need to use the voltage-specific value. At 55 °C it derates to 158 A, at 60 °C to 155 A, at 65 °C to 153 A, and at 70 °C to 150 A. That is a shallow derating curve — only 10 A lost over a 30 °C rise — so in a warm panel or outdoor enclosure the breaker still carries nearly its full nameplate. That 76.2 mm width is a standard 3-inch footprint for a 3-pole MCCB in this class — it matches the mounting hole pattern and bus-bar spacing of the SENTRON 3VA family. The unit includes an undervoltage release but no auxiliary contact, no communication function, and no ground-fault monitoring. If you need remote status or shunt-trip capability, you add the accessory separately.","metaTitle":"Siemens 3VA1116-6EE32-0DA0 SENTRON MCCB, 160 A, 3-Pole, TM22","metaDescription":"Siemens 3VA1116-6EE32-0DA0 SENTRON molded case circuit breaker, 160 A at 40 °C, 3-pole, TM220 release, 220 kA at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"220 kA","at 415 V":"154 kA","at 440 V":"75.6 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"158 A","at 60 °C":"155 A","at 65 °C":"153 A","at 70 °C":"150 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"Yes","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"40.5 W","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","rated insulation voltage Ui":"800 V","Of The Supplied Basic Switch":"3VA11166EE320AA0","Courant permanent assigné Iu":"63 A","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"TM220","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","reference code / acc. to IEC 81346-2":"Q","Of The Integrated Auxiliary Trip Unit":"3VA9608-0BB25","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / li max.":"630 A","Adjustable response value current / li min.":"630 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Max. rated operational current of the frame size":"160 A","Mechanical Service Life (Switching Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5 mm","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=362459&mlfb=3VA1116-6EE32-0DA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1116-6EE32-0DA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA1116-6EE32-0DA0?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels."},{"question":"What are the physical dimensions of 3VA1116-6EE32-0DA0?","answer":"Height 130 mm, width 76.2 mm, depth 70 mm. The 76.2 mm (3-inch) width is standard for a 3-pole MCCB in this frame class."},{"question":"Will 3VA1116-6EE32-0DA0 drop into a panel specified around 3VA1112-5EE32-0AA0 without rewiring?","answer":"The 3VA1116-6EE32-0DA0 is a higher-current frame (160 A vs the lower-rated 3VA1112 variant). While the physical width and mounting pattern are the same SENTRON 3VA family, the bus-bar and cable sizing must be verified for 160 A — you cannot assume the same wiring works without checking ampacity."},{"question":"What compliance documentation does Siemens provide for 3VA1116-6EE32-0DA0?","answer":"Siemens SENTRON MCCBs typically carry IEC 60947-2 and UL 489 certifications. Specific RoHS and REACH declarations are available through Siemens Industry Online Support for this order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-6EE32-0DA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-6EE32-0DA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}