{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-6GD42-0AA0-ZD00","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-6GD42-0AA0-ZD00","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-6GD42-0AA0-ZD00","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-6GD42-0AA0-ZD00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 160, breaking capacity class H, 4-pole circuit breaker, 70kA Icu at 415V, fixed thermal-magnetic TM210 protection, 160A rated current, fixed short-circuit release at 10 x In, N-conductor protection at 100%, nut keeper kit, OEM for DC Power in China.","salesMarkdown":"The Siemens 3VA1116-6GD42-0AA0-ZD00 is a 4-pole IEC frame 160 molded-case circuit breaker rated for line protection with a TM210 thermal-magnetic trip unit. Its headline figure is the 70 kA breaking capacity at 415 V (class H), which means it can safely interrupt fault currents up to that level without upstream coordination issues — critical for high-fault panels or transformer-fed switchboards where the available short-circuit current exceeds 50 kA. ## Ratings and deployment Fixed overload protection set at Ir = 160 A, with short-circuit pickup fixed at Ii = 10 × In (1600 A). The N-conductor protection is set to 100% — this breaker protects the neutral at full phase rating, which matters for panels feeding non-linear loads where neutral harmonics can exceed phase current.","metaTitle":"Siemens 3VA1116-6GD42-0AA0-ZD00 Circuit Breaker, 160A, 70kA","metaDescription":"Siemens 3VA1116-6GD42-0AA0-ZD00 IEC frame 160 circuit breaker, 70kA breaking capacity at 415V, 4-pole, 160A fixed thermal-magnetic protection. Current production lifecycle stage. A","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1667612&mlfb=3VA1116-6GD42-0AA0-ZD00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1116-6GD42-0AA0-ZD00/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this breaker?","answer":"The 3VA1116-6GD42-0AA0-ZD00 has a breaking capacity class H with Icu = 70 kA at 415 V, suitable for high-fault panels."},{"question":"Where can I buy 3VA1116-6GD42-0AA0-ZD00?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What does the TM210 trip unit mean?","answer":"TM210 indicates a fixed thermal-magnetic trip unit: thermal overload protection fixed at Ir = 160 A, and magnetic short-circuit protection fixed at Ii = 10 × In (1600 A)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-6GD42-0AA0-ZD00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-6GD42-0AA0-ZD00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}