{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1116-6GF46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1116-6GF46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1116-6GF46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1116-6GF46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1116-6GF46-0AA0, molded case circuit breaker, 160 A, 4-pole, TM240 thermal-magnetic release, line protection design.","salesMarkdown":"## What this 160 A MCCB delivers in the panel It's built for main feeder or large subfeed duty in distribution panels where you need a full 160 A frame — no derating down to a smaller continuous rating. The interrupting capacity sits at 220 kA at 240 V, 154 kA at 415 V, and still holds 17 kA at 690 V, so it handles high-fault scenarios without cascading upstream. Above that, it derates: 158 A at 55 °C, 155 A at 60 °C, 153 A at 65 °C, and 150 A at 70 °C. Maximum power loss is 38 W. If you're packing this into a high-density enclosure, that thermal curve and loss figure tell you where the ventilation needs to be. Dimensions are 101.6 mm wide, 130 mm tall, 70 mm deep — a 4-inch-wide footprint that matches the standard SENTRON 3VA frame.","metaTitle":"Siemens 3VA1116-6GF46-0AA0 SENTRON MCCB, 160 A, 4-Pole, TM24","metaDescription":"Siemens 3VA1116-6GF46-0AA0 SENTRON molded case circuit breaker, 160 A, 4-pole, TM240 release, 220 kA at 240 V. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"101.6 mm","Height":"130 mm","Maximum":"160 A","Minimum":"160 A","at 240 V":"220 kA","at 415 V":"154 kA","at 440 V":"75.6 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"160 A","at 45 °C":"160 A","at 50 °C":"160 A","at 55 °C":"158 A","at 60 °C":"155 A","at 65 °C":"153 A","at 70 °C":"150 A","Depth [In]":"2.76 in","Width [In]":"4 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"4","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"38 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM240","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","design of the N-conductor protection":"100%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"600 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/859b686eac2947f481f72a2db73cb48b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=2206&mlfb=3VA1116-6GF46-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1116-6GF46-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1116-6GF46-0AA0 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is 3VA1116-6GF46-0AA0's interrupting capacity at 415 V?","answer":"At 415 V, the interrupting capacity is 154 kA. At 240 V it's 220 kA, at 440 V it's 75.6 kA, and at 500 V or 690 V it's 17 kA."},{"question":"What does the TM240 release designation mean?","answer":"TM240 is a thermal-magnetic release with a fixed thermal pickup and magnetic trip setting. For this 160 A frame, the TM240 release provides line protection — overload protection via the thermal element and short-circuit protection via the magnetic element."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1116-6GF46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1116-6GF46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}