{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1120-5EE46-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1120-5EE46-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1120-5EE46-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1120-5EE46-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1120-5EE46-0AA0, 4-pole molded case circuit breaker, 20 A rated current, TM220 thermal-magnetic release, breaking capacity 187 kA at 240 V AC.","salesMarkdown":"## What this 4-pole MCCB delivers Its interrupting capacity hits 187 kA at 240 V AC, 121 kA at 415 V, and 75.6 kA at 440 V — numbers that put it in the high-fault category for industrial distribution panels where available short-circuit current is substantial. That gives you some tuning for inrush without changing the breaker — useful on motor or transformer feeders where the starting surge exceeds the continuous rating but the cable still needs the 20 A thermal protection. ## Sourcing and lifecycle — current production, no LTB signal This breaker is in the current lifecycle stage — no end-of-life or last-time-buy notice. It remains a standard catalog item in the SENTRON 3VA family. The 3VA1120-5EE46-0AA0 measures 70 mm deep, 101.6 mm wide, and 130 mm tall. That 101.6 mm width (4 inches) is a standard 4-pole MCCB footprint — it occupies four 25 mm module positions on a DIN rail or a direct-mount backplate. The IP40 front protection means it is splash-safe from the front but not sealed; mount it inside a panel that provides the overall enclosure rating. The 800 V rated insulation voltage (Ui) gives headroom for 690 V systems — the 17 kA breaking capacity at 690 V confirms it can clear faults on 690 V line-to-line circuits, though that is a derated capability compared to the 187 kA at 240 V. The 600 V DC maximum operational voltage (Ue with DC) means it can also serve as a DC switch/disconnect in battery or rectifier circuits up to that voltage, provided the DC current and time constant stay within the manufacturer's DC derating curves. Thermal derating is minimal across the operating range: the breaker holds 20 A from 45 °C through 55 °C, then drops only 1 A at 60 °C and stays at 19 A through 70 °C. That flat curve simplifies panel design — no need to oversize for a warm cabinet unless ambient exceeds 70 °C.","metaTitle":"Siemens 3VA1120-5EE46-0AA0 SENTRON MCCB, 4P, 20 A, 187 kA","metaDescription":"Siemens 3VA1120-5EE46-0AA0 SENTRON molded case circuit breaker, 4-pole, 20 A rated, TM220 release, breaking capacity 187 kA at 240 V. Current lifecycle stage. Sourced to order agai","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"101.6 mm","Height":"130 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"75.6 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 45 °C":"20 A","at 50 °C":"20 A","at 55 °C":"20 A","at 60 °C":"19 A","at 65 °C":"19 A","at 70 °C":"19 A","Depth [In]":"2.76 in","Width [In]":"4 in","Height [In]":"5.12 in","Number Of Poles":"4","Product version":"Line protection","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"12 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Courant permanent assigné Iu":"20 A","Ground-Fault Monitoring Version":"Without","Tension assignée d'isolement Ui":"800 V","Design Of The Overcurrent Release":"TM220","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","design of the N-conductor protection":"Without","reference code / acc. to IEC 81346-2":"Q","Max. rated operational voltage Ue with DC":"600 V","Product Extension / Optional / Motor Drive":"Yes","Adjustable response value current / li max.":"320 A","Adjustable response value current / li min.":"320 A","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Max. rated operational current of the frame size":"160 A","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=3905&mlfb=3VA1120-5EE46-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1120-5EE46-0AA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1120-5EE46-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1120-5EE46-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}