{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1120-6EF32-0AH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1120-6EF32-0AH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1120-6EF32-0AH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1120-6EF32-0AH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1120-6EF32-0AH0, molded case circuit breaker, 3-pole, 20 A rated continuous current, 220 kA interrupting capacity at 240 V, TM240 thermal-magnetic release, 2 aux + 1 alarm switch.","salesMarkdown":"## SENTRON 3VA1120-6EF32-0AH0 — 20 A MCCB for Line Protection The Siemens 3VA1120-6EF32-0AH0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for line protection duty, carrying a continuous current Iu of 20 A that holds flat from 40 °C up to 50 °C before a gradual derating curve begins — at 55 °C it's still 19.2 A, and at the 70 °C operating maximum it delivers 18 A. That thermal stability means you can size this breaker for a 20 A feeder in a warm panel without oversizing the frame. The interrupting ratings are the headline here: 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at 690 V. ## Panel Fit — Dimensions and Mounting The 3VA1120-6EF32-0AH0 measures 76.2 mm wide, 130 mm tall, and 70 mm deep — a standard 3-pole MCCB footprint that fits SENTRON distribution blocks and most DIN-rail or screw-mount panel layouts.","metaTitle":"Siemens 3VA1120-6EF32-0AH0 SENTRON MCCB, 20 A, 220 kA at 240","metaDescription":"Siemens 3VA1120-6EF32-0AH0 SENTRON molded case circuit breaker, 20 A rated, 220 kA interrupting at 240 V. Current production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"220 kA","at 415 V":"154 kA","at 440 V":"121 kA","at 690 V":"17 kA","at 40 °C":"20 A","at 45 °C":"20 A","at 50 °C":"20 A","at 55 °C":"19.2 A","at 60 °C":"18.8 A","at 65 °C":"18.4 A","at 70 °C":"18 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"20 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"without auxiliaryrelease","Ground fault monitoring version":"Without","Design of the overcurrent release":"TM240","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"20 A","Adjustable response value current / li max.":"320 A","Adjustable response value current / li min.":"160 A","Adjustable response value current / lr min.":"14 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"H","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=384326&mlfb=3VA1120-6EF32-0AH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1120-6EF32-0AH0/alternatives.json"},"ai":{"faq":[{"question":"How do I get pricing and availability for 3VA1120-6EF32-0AH0?","answer":"Pricing and stock are confirmed at quote time against an RFQ. Submit a request through the storefront and we'll return current availability and a firm price for your quantity."},{"question":"What is the interrupting capacity of this MCCB at 240 V?","answer":"At 240 V the interrupting rating is 220 kA. At 415 V it's 154 kA, at 440 V it's 121 kA, and at 690 V it's 17 kA."},{"question":"What does the TM240 release designation mean?","answer":"TM240 indicates a thermal-magnetic overcurrent release with fixed settings — the thermal element provides overload protection, the magnetic element provides short-circuit protection, and the '240' refers to the release family within the 3VA platform. No field adjustment of trip curves is available on this variant."},{"question":"What auxiliary contacts come with this breaker?","answer":"It ships with 2 auxiliary switches plus 1 trip alarm switch (HQ type), giving you remote position indication and a dedicated alarm contact for trip events."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1120-6EF32-0AH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1120-6EF32-0AH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}