{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1132-3EF36-0JA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1132-3EF36-0JA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1132-3EF36-0JA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1132-3EF36-0JA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1132-3EF36-0JA0, Molded case circuit breaker, 3-pole, 32 A, line protection, TM240 overcurrent release, shunt trip, IP40 front.","salesMarkdown":"## SENTRON 3VA1132-3EF36-0JA0 — 32 A MCCB with Shunt Trip The interrupting ratings scale with system voltage: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 10.5 kA at 690 V. At 415 V, that SCCR covers most industrial secondary-distribution fault levels without cascading upstream — a key selectivity consideration for panel builders coordinating downstream branch breakers. Current rating holds flat at 32 A up to 50 °C ambient, then derates to 30.72 A at 55 °C and 28.8 A at 70 °C. The breaker carries an integrated auxiliary trip accessory (order code 3VA9688-0BL32) that ships as a factory-fitted component on this variant. If you are replacing a unit in the field, confirm the shunt trip coil voltage matches your control circuit — the base breaker does not include undervoltage release or auxiliary contacts. The 3VA1132-3EF36-0JA0 measures 76.2 mm wide by 130 mm tall by 70 mm deep — a standard 3-pole MCCB footprint that fits Siemens SENTRON distribution panels and most DIN-rail-mount enclosures with the appropriate adapter.","metaTitle":"Siemens 3VA1132-3EF36-0JA0 SENTRON MCCB, 32 A, 3-Pole, Line","metaDescription":"Siemens 3VA1132-3EF36-0JA0 SENTRON molded case circuit breaker, 32 A rated continuous current, 3-pole, line protection. 75.6 kA at 240 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","title":"3VA1132-3EF36-0JA0","Height":"130 mm","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 690 V":"10.5 kA","at 40 °C":"32 A","at 45 °C":"32 A","at 50 °C":"32 A","at 55 °C":"30.72 A","at 60 °C":"30.08 A","at 65 °C":"29.44 A","at 70 °C":"28.8 A","description":"circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM240, ATAM, In=32A overload protection Ir=22A...32A short-circuit protection Ii=5...10 x In clamp connection shunt trip (STL) 110-127V DC, AC 50/60Hz","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"Yes","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"Without","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"32 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Shunt trip (STL)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9688-0BL32","Design of the overcurrent release":"TM240","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"32 A","Adjustable response value current / li max.":"320 A","Adjustable response value current / li min.":"160 A","Adjustable response value current / lr min.":"22 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"0","Protective function of the overcurrent release":"LI","Switching capacity class of the circuit breaker":"N","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"box terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, round conductor terminal, stranded":"1 x (1.5 - 70 mm²)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c3de18f10dd52266f770fd73388f1ee5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=55240&mlfb=3VA1132-3EF36-0JA0"},"ai":{"faq":[{"question":"What is the interrupting rating of 3VA1132-3EF36-0JA0 at 415 V?","answer":"52.5 kA at 415 V, which covers most industrial secondary-distribution fault levels without requiring an upstream current-limiting fuse."},{"question":"Does this MCCB include a shunt trip or undervoltage release?","answer":"It includes a shunt trip (STL) auxiliary release for remote voltage-triggered tripping, but does not include an undervoltage release or auxiliary contacts."},{"question":"Where can I buy 3VA1132-3EF36-0JA0?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time."},{"question":"What is the ambient temperature derating for this breaker?","answer":"Rated 32 A continuous up to 50 °C, then derates to 30.72 A at 55 °C and 28.8 A at 70 °C. The full thermal curve is listed in the specs."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1132-3EF36-0JA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1132-3EF36-0JA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}