{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1132-4ED36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1132-4ED36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1132-4ED36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1132-4ED36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1132-4ED36-0AA0, molded case circuit breaker, 3-pole, 32 A, TM210 thermal-magnetic trip unit, line protection, 70 mm depth.","salesMarkdown":"The 3VA1132-4ED36-0AA0: This 3-pole MCCB delivers 121 kA breaking capacity at 240 V AC, dropping to 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. The high 121 kA figure at 240 V makes it suitable for high-fault service-entrance or panelboard applications where upstream transformer impedance is low. At 415 V the 75.6 kA rating provides headroom for most industrial distribution — the SCCR of downstream equipment can be coordinated against this value. At 55 °C it derates to 31 A, holding there through 60 °C, then to 30 A at 65 °C and 70 °C. For a panel with internal temperature rise, the 30 A floor at 70 °C means the breaker can be applied in a fully loaded enclosure without forced cooling, as long as the continuous load stays under that figure. Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a standard 3-pole MCCB footprint that fits SENTRON 3VA mounting accessories and busbar systems.","metaTitle":"Siemens 3VA1132-4ED36-0AA0 SENTRON MCCB, 32 A, 3-Pole, 70 mm","metaDescription":"Siemens SENTRON 3VA1132-4ED36-0AA0 molded case circuit breaker, 32 A at 40 °C, 3-pole, TM210 trip unit. Breaking capacity 121 kA at 240 V, 75.6 kA at 415 V. Active production. Sour","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"121 kA","at 415 V":"75.6 kA","at 440 V":"52.5 kA","at 500 V":"11.9 kA","at 690 V":"11.9 kA","at 40 °C":"32 A","at 45 °C":"32 A","at 50 °C":"32 A","at 55 °C":"31 A","at 60 °C":"31 A","at 65 °C":"30 A","at 70 °C":"30 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10.6 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"S","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c3de18f10dd52266f770fd73388f1ee5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=153061&mlfb=3VA1132-4ED36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1132-4ED36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA1132-4ED36-0AA0?","answer":"Submit an RFQ through the storefront. This part is sourced to order through independent distribution, and the current price and stock position are confirmed at quote time."},{"question":"What is the breaking capacity of 3VA1132-4ED36-0AA0 at 415 V?","answer":"75.6 kA at 415 V AC. At 240 V it is 121 kA, at 440 V it is 52.5 kA, and at 500 V and 690 V it is 11.9 kA."},{"question":"What trip unit does 3VA1132-4ED36-0AA0 use?","answer":"The TM210 thermal-magnetic trip unit, providing fixed thermal and magnetic protection settings for line protection duty."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1132-4ED36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1132-4ED36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}