{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1132-5EF36-0CA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1132-5EF36-0CA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1132-5EF36-0CA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1132-5EF36-0CA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 160, breaking capacity class M, 3-pole, 55kA @ 415V, 32A, TM240, ATAM, undervoltage release 120-127V AC.","salesMarkdown":"The Siemens 3VA1132-5EF36-0CA0 is a 3-pole IEC frame 160 circuit breaker from the 3VA1 series, rated for line protection with a TM240 thermal-magnetic trip unit. Rated at In = 32 A, the overload protection is adjustable via Ir from 22 A to 32 A, and the short-circuit pickup Ii is set at 5 to 10 times In. Clamp-type terminals simplify panel wiring. The clamp terminals accept copper conductors up to the frame's rated cross-section, and the UVR coil draws its control voltage from a separate 120–127 V AC supply.","metaTitle":"Siemens 3VA1132-5EF36-0CA0 Circuit Breaker, 55kA @ 415V, 32A","metaDescription":"Siemens 3VA1132-5EF36-0CA0 IEC frame 160 circuit breaker, 55kA breaking capacity @ 415V, 32A with undervoltage release. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c3de18f10dd52266f770fd73388f1ee5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=78608&mlfb=3VA1132-5EF36-0CA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1132-5EF36-0CA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this breaker?","answer":"The rated ultimate breaking capacity Icu is 55 kA at 415 V AC, class M, which covers most industrial distribution panels with fault levels up to that threshold."},{"question":"Does this breaker include an undervoltage release?","answer":"Yes, it is fitted with an undervoltage release (UVR) rated for 120–127 V AC, 50/60 Hz. The UVR will trip the breaker if the control voltage drops below its dropout threshold."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1132-5EF36-0CA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1132-5EF36-0CA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}