{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1132-6ED32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1132-6ED32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1132-6ED32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1132-6ED32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1, Molded case circuit breaker, 3-pole, 32 A, TM210 release, 220 kA at 240 V, 70 mm depth, 76.2 mm width, IP40 front.","salesMarkdown":"The Siemens 3VA1132-6ED32-0AA0 is a SENTRON 3-pole molded case circuit breaker (MCCB) carrying a 32 A continuous rating at 40 °C through 50 °C, derating to 30 A at 70 °C. It's built for line protection — meaning it sits on the incoming feeder side of a panel, not downstream on a motor branch — and uses a TM210 thermal-magnetic release that gives you fixed thermal pickup with magnetic trip factory-set at 10× In. That's a standard distribution breaker: no adjustable trip curves, no ground-fault module, no communication module. If the BOM calls for a simple, high-interrupting MCCB for a main or subfeed, this is the one. This breaker's interrupting rating is voltage-dependent, and the spread matters. At 240 V it clears 220 kA — that's a very high fault-current capacity for a 32 A frame, typical for a main breaker close to a large transformer. At 415 V it's still 154 kA, and at 440 V it holds 121 kA. The drop to 17 kA at 500 V and 690 V tells you the arc extinction is optimized for the 240–440 V range. Above 500 V, you need to check the 17 kA limit against your transformer's nameplate impedance. Footprint is 76.2 mm wide by 130 mm tall by 70 mm deep — a standard 3-pole MCCB width that drops into most SENTRON or 3VA-series panelboard mounting plates without adapter brackets.","metaTitle":"Siemens 3VA1132-6ED32-0AA0 SENTRON MCCB, 32 A, 220 kA at 240","metaDescription":"Siemens 3VA1132-6ED32-0AA0 SENTRON 3-pole molded case circuit breaker, 32 A rated, TM210 release, 220 kA breaking at 240 V. Current production, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"220 kA","at 415 V":"154 kA","at 440 V":"121 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"32 A","at 45 °C":"32 A","at 50 °C":"32 A","at 55 °C":"31 A","at 60 °C":"31 A","at 65 °C":"30 A","at 70 °C":"30 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Product version":"Line protection","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10.6 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","rated insulation voltage Ui":"800 V","Ground-Fault Monitoring Version":"Without","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","operating voltage / at AC / rated value":"690 V","Max. rated operational voltage Ue with DC":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Neutral conductors / upgradeable/retrofittable":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Switching Cycles) / Typical":"20 000","reference value setting current (Ii) / for I-tripping":"x In","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","type of value list setting current (Ii) / for I-tripping":"Fest","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6,5 mm","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 1 mm"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c3de18f10dd52266f770fd73388f1ee5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=57143&mlfb=3VA1132-6ED32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1132-6ED32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this MCCB at different voltages?","answer":"At 240 V it clears 220 kA, at 415 V it clears 154 kA, at 440 V it clears 121 kA, and at 500 V and 690 V it clears 17 kA. The high ratings at 240–440 V make it suitable for main breaker duty near large transformers."},{"question":"What are the mounting dimensions for 3VA1132-6ED32-0AA0?","answer":"Width is 76.2 mm, height is 130 mm, depth is 70 mm. It fits standard 3-pole MCCB mounting patterns without adapters."},{"question":"Where can I buy 3VA1132-6ED32-0AA0?","answer":"This part is available to order through our sourcing desk. Submit an RFQ and we'll confirm current pricing and availability at quote time — no stock figures or lead-time numbers on the listing, but we source it direct from Siemens distribution channels."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1132-6ED32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1132-6ED32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}