{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1132-6ED32-0AA0-ZD00","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1132-6ED32-0AA0-ZD00","canonicalUrl":"https://aoctrl.com/siemens/3VA1132-6ED32-0AA0-ZD00","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1132-6ED32-0AA0-ZD00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 160, 3-pole circuit breaker, breaking capacity class H, Icu=70kA @ 415V, line protection TM210, FTFM, In=32A, Ir=32A fixed, Ii=10 x In, nut keeper kit for DC Power OEM in China.","salesMarkdown":"The Siemens 3VA1132-6ED32-0AA0-ZD00 is a 3-pole IEC frame 160 molded case circuit breaker rated for 32 A continuous load with a fixed thermal-magnetic trip (TM210, FTFM). For a 32 A frame, that's a high-interrupting-capability (class H) device, sized for high-fault locations like a main distribution panel or a transformer secondary where available fault current is stiff. The overload protection (Ir) is fixed at 32 A — no adjustment dial. The short-circuit pickup (Ii) is fixed at 10 x In, so 320 A instantaneous. That means it's a straight thermal-magnetic breaker with a fixed curve; you're not going to dial in a lower pickup for a motor start or a transformer inrush. It's line protection, not motor protection. The fixed Ir and Ii make it a drop-in replacement for a BOM line that already specifies those exact settings.","metaTitle":"Siemens 3VA1132-6ED32-0AA0-ZD00 Circuit Breaker, 32A, 70kA @","metaDescription":"Siemens 3VA1132-6ED32-0AA0-ZD00 IEC frame 160 circuit breaker, 3-pole, 32A, 70kA breaking capacity @ 415V. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c3de18f10dd52266f770fd73388f1ee5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1667714&mlfb=3VA1132-6ED32-0AA0-ZD00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1132-6ED32-0AA0-ZD00/alternatives.json"},"ai":{"faq":[{"question":"What is 3VA1132-6ED32-0AA0-ZD00's breaking capacity?","answer":"It has a breaking capacity class H with Icu = 70 kA at 415 V AC, 3-pole. That's the ultimate short-circuit breaking capacity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1132-6ED32-0AA0-ZD00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1132-6ED32-0AA0-ZD00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}