{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1132-6ED42-0AA0-ZD00","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1132-6ED42-0AA0-ZD00","canonicalUrl":"https://aoctrl.com/siemens/3VA1132-6ED42-0AA0-ZD00","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1132-6ED42-0AA0-ZD00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1132-6ED42-0AA0-ZD00, 3VA1 IEC frame 160, breaking capacity class H, Icu=70kA @ 415V, 4-pole, TM210 line protection, In=32A, Ir=32A fixed, Ii=10 x In, N conductor unprotected, nut keeper kit for DC Power OEM in China.","salesMarkdown":"## What this 3VA1 MCCB carries The Siemens 3VA1132-6ED42-0AA0-ZD00 is a 4-pole IEC frame 160 molded case circuit breaker in breaking capacity class H, rated Icu=70kA at 415 VAC. That 70 kA interrupting rating means it can safely clear a fault up to that level without upstream fuses or a larger-frame breaker — a real advantage in high-fault panels where selectivity matters. The TM210 thermal-magnetic trip unit is fixed at In=32 A with Ir=32 A overload protection and short-circuit pickup Ii=10 x In (320 A). The N conductor is unprotected (no overload sensing on the neutral), which is standard for line-side protection where the neutral is not expected to carry unbalanced load current. ## Panel integration and sourcing The 3VA1 frame 160 mounts on a DIN rail or can be screw-fixed to a backplate. At 32 A fixed Ir, there is no adjustment range on the overload — the breaker ships set for that exact load. The nut keeper kit is included for the DC Power OEM build; if you are replacing an existing unit in a panel, verify the neutral conductor is indeed unprotected (no neutral CT) before ordering.","metaTitle":"Siemens 3VA1132-6ED42-0AA0-ZD00 3VA1 IEC Frame 160 MCCB, 32A","metaDescription":"Siemens 3VA1132-6ED42-0AA0-ZD00 circuit breaker, 3VA1 IEC frame 160, breaking capacity class H Icu=70kA @ 415V, 4-pole, TM210, In=32A. Current lifecycle stage. Quoted to order agai","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c3de18f10dd52266f770fd73388f1ee5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1667715&mlfb=3VA1132-6ED42-0AA0-ZD00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1132-6ED42-0AA0-ZD00/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting rating of this breaker?","answer":"The breaking capacity class H gives Icu=70kA at 415 VAC, which is the maximum short-circuit current the breaker can safely interrupt at that voltage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1132-6ED42-0AA0-ZD00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1132-6ED42-0AA0-ZD00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}