{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1132-6EF36-0HA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1132-6EF36-0HA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1132-6EF36-0HA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1132-6EF36-0HA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1 molded case circuit breaker, 3VA1132-6EF36-0HA0, 3-pole, 32 A (40 °C), 220 kA at 240 V AC, line protection, TM240 thermal-magnetic release, shunt trip (STL).","salesMarkdown":"It carries a continuous current rating of 32 A at 40 °C ambient, with no derating needed up to 50 °C — still 32 A at 50 °C — and only a 2 A drop at 70 °C (30 A). That thermal stability means it holds its full rating across most panel interior temperatures without oversizing. The interrupting ratings are what set this frame apart: 220 kA at 240 V AC, 154 kA at 415 V, and 121 kA at 440 V. Those numbers put it in the high-breaking-capacity class — suitable for large transformer secondaries or busway feeds where fault current runs high. The built-in shunt trip (STL) allows remote tripping via a control voltage, which is useful for emergency-stop circuits or interlocking schemes. The 3VA1132-6EF36-0HA0 measures 76.2 mm wide (3 in), 130 mm tall (5.12 in), and 70 mm deep (2.76 in). The 3-pole width matches the standard 3-inch-per-pole spacing for SENTRON 3VA1 frames. Maximum power dissipation is 10.6 W, which should be factored into enclosure thermal calculations. That covers most indoor and sheltered outdoor installations. No IP rating is listed, so it is intended for enclosed panel mounting, not washdown or outdoor exposure.","metaTitle":"Siemens 3VA1132-6EF36-0HA0 SENTRON MCCB, 32 A, 220 kA at 240","metaDescription":"Siemens 3VA1132-6EF36-0HA0 SENTRON molded case circuit breaker, 3-pole, 32 A rated at 40 °C, 220 kA breaking capacity at 240 V AC. Shunt trip release. Active production. Quoted to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"220 kA","at 415 V":"154 kA","at 440 V":"121 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"32 A","at 45 °C":"32 A","at 50 °C":"32 A","at 55 °C":"31 A","at 60 °C":"31 A","at 65 °C":"30 A","at 70 °C":"30 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"10.6 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA11326EF360AA0","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM240","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL30","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c3de18f10dd52266f770fd73388f1ee5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=337355&mlfb=3VA1132-6EF36-0HA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1132-6EF36-0HA0/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of 3VA1132-6EF36-0HA0 at 240 V?","answer":"The interrupting rating is 220 kA at 240 V AC. At 415 V it is 154 kA, at 440 V it is 121 kA, and at 500 V and 690 V it is 17 kA."},{"question":"Does this MCCB have a shunt trip?","answer":"Yes, it includes a shunt trip (STL) auxiliary release for remote tripping. It does not include an undervoltage release or ground-fault monitoring."},{"question":"Where can I buy 3VA1132-6EF36-0HA0 and how is it quoted?","answer":"This part is sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1132-6EF36-0HA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1132-6EF36-0HA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}