{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1150-6ED36-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1150-6ED36-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1150-6ED36-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1150-6ED36-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1150-6ED36-0AA0, 3-pole molded case circuit breaker, 50 A continuous (500 A frame), TM210 thermal-magnetic release, 220 kA breaking capacity at 240 V AC, 70 mm depth.","salesMarkdown":"## Siemens SENTRON 3VA1150-6ED36-0AA0 — 50 A MCCB, 500 A Frame, TM210 Release The Siemens SENTRON 3VA1150-6ED36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 50 A continuous current on a 500 A frame, with a TM210 thermal-magnetic overcurrent release. It delivers a 220 kA interrupting capacity at 240 V AC, stepping down to 154 kA at 415 V, 121 kA at 440 V, and 17 kA at both 500 V and 690 V. ## Thermal Derating and Ambient Heat — What 70 °C Means on a Mill Floor Rated 50 A all the way from 40 °C to 50 °C ambient, then it starts to pull back: 49 A at 55 °C, 48 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C. For a hot-strip mill panel sitting near the runout table or furnace zone, that 70 °C ceiling with only 10 % derating (45 A vs 50 A) means this MCCB holds its strip without nuisance tripping when the ambient climbs. Measures 76.2 mm wide (3 in), 130 mm tall (5.12 in), and 70 mm deep (2.76 in). That 76.2 mm width is the standard 3-pole MCCB footprint for a 500 A frame — drops into the same DIN-rail or panel-mount cutout as other SENTRON 3VA frame breakers.","metaTitle":"3VA1150-6ED36-0AA0 SENTRON MCCB, 50 A, 500 A Frame, 220 kA a","metaDescription":"Siemens SENTRON 3VA1150-6ED36-0AA0 molded case circuit breaker, 3-pole, 50 A continuous, 500 A frame, 220 kA breaking at 240 V. TM210 release. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"500 A","Minimum":"500 A","at 240 V":"220 kA","at 415 V":"154 kA","at 440 V":"121 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"50 A","at 45 °C":"50 A","at 50 °C":"50 A","at 55 °C":"49 A","at 60 °C":"48 A","at 65 °C":"46 A","at 70 °C":"45 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"14.6 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"50 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"H","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3701e11a2ead145be1b4bac08ae9e3c8.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=463314&mlfb=3VA1150-6ED36-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1150-6ED36-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1150-6ED36-0AA0 and what is the lead time?","answer":"Sourced to order through independent distribution against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or lead-time number posted here."},{"question":"What is the breaking capacity of 3VA1150-6ED36-0AA0 at different voltages?","answer":"220 kA at 240 V AC, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at both 500 V and 690 V AC."},{"question":"What does the TM210 overcurrent release mean on this MCCB?","answer":"The TM210 is a thermal-magnetic release — the thermal element handles overload protection (time-delayed), the magnetic element handles short-circuit protection (instantaneous). It's the standard release for line protection in the SENTRON 3VA series."},{"question":"What is the operating temperature range for 3VA1150-6ED36-0AA0?","answer":"-25 °C to 70 °C during operation, with a storage range of -40 °C to 80 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1150-6ED36-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1150-6ED36-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}