{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1163-1AA36-0JC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1163-1AA36-0JC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1163-1AA36-0JC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1163-1AA36-0JC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1163-1AA36-0JC0, switch disconnector in MCCB design, IEC frame 160, 3-pole, SD100, In=63 A, without overload or short-circuit protection, clamp connection, shunt trip (STL) 110-127 V DC/AC 50/60 Hz, 2 auxiliary switches HQ.","salesMarkdown":"It's built as a pure isolator — no overload or short-circuit protection onboard, just a manual disconnect with a shunt trip (STL) coil for remote opening. The shunt trip fires on 110-127 V DC or AC 50/60 Hz, so you can drop the load from a PLC dry contact or an E-stop string without running a handle through the panel door. Two HQ auxiliary switches (form C, 2 CO contacts) come integrated, giving you status feedback for the panel PLC or a local indicator lamp. The front-terminal clamp connection accepts standard copper lugs — no special crimp tool needed for field wiring. Same 70 mm depth and 76.2 mm width as the rest of the 3VA1 160 A frame family — it drops into the same DIN-rail or screw-mount footprint as a 3VA1 MCCB. If you're swapping a breaker for a disconnect-only unit in an existing panel, the bus-bar spacing and terminal layout match. The front-terminal clamp connection means you don't have to rework the gland plate or re-route cables. 63 A rated continuous current (Iu) means it carries that load indefinitely at 40 °C ambient without derating — sized for a 60 A feeder or a motor branch circuit where the upstream breaker handles the fault interruption. The 800 V rated insulation voltage (Ui) covers 480 V and 600 V class systems with margin; the 690 V AC / 500 V DC max operational voltage (Ue) matches typical industrial supply voltages. 15 000 mechanical operations endurance — good for daily switching in a machine tool or conveyor line, but not rated for continuous-duty motor starting (that's what a contactor is for). The 38 W max power loss is the heat dissipated at full rated current; factor that into your panel thermal budget if you're stacking several units.","metaTitle":"Siemens 3VA1163-1AA36-0JC0 SENTRON Switch Disconnector, 63 A","metaDescription":"Siemens SENTRON 3VA1163-1AA36-0JC0 switch disconnector, 63 A rated continuous current, 3-pole, with shunt trip STL 110-127 V DC/AC and 2 HQ auxiliary switches. Active production, s","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Limited To 1 S":"2 kA","Trip indicator":"No","Number of poles":"3","Product version":"in MCCB design","Voltage trigger":"Yes","lifecycle_stage":"current","Limited To 0.5 S":"2 kA","Product brand name":"SENTRON","Product designation":"Switch disconnector","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"38 W","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Rated continuous current Iu":"63 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Shunt trip (STL)","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Number of CO contacts / for auxiliary contacts":"2","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Terminal connection","Arrangement of electrical connectors / for main current circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=326871&mlfb=3VA1163-1AA36-0JC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1163-1AA36-0JC0/alternatives.json"},"ai":{"faq":[{"question":"Will 3VA1163-1AA36-0JC0 drop into a panel specified for 3VA1010-2ED32-0JC0?","answer":"Yes — same 70 mm depth, 76.2 mm width, 130 mm height, and front-terminal layout. The disconnect-only unit fits the same bus-bar and DIN-rail footprint as the MCCB version. No rewiring needed if the panel already has the shunt trip and auxiliary contact wiring in place."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1163-1AA36-0JC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1163-1AA36-0JC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}