{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1163-1AA36-0KH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1163-1AA36-0KH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1163-1AA36-0KH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1163-1AA36-0KH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1 IEC frame 160, switch disconnector, 3-pole SD100, In=63 A, without overload or short-circuit protection, shunt trip (STL) 220-250 V DC; 208-277 V AC, 2 auxiliary switches HQ + 1 trip alarm switch HQ, front terminal connection.","salesMarkdown":"The Siemens SENTRON 3VA1163-1AA36-0KH0 is a 3-pole switch disconnector in the 3VA1 IEC frame 160 family, rated for a continuous current Iu of 63 A. It is designed for load-break isolation — it opens and closes a circuit under load but provides no overload or short-circuit protection (that is what the upstream MCCB or fuse handles). The integrated shunt trip (STL) allows remote tripping on a control signal: 220–250 V DC or 208–277 V AC. Rated insulation voltage Ui is 800 V, and the maximum operational voltage reaches 690 V AC (50/60 Hz) or 500 V DC. The short-time withstand current is 2 kA at both 0.5 s and 1 s — this is the fault current the disconnector can carry without damage while the upstream protective device clears. It is not a breaking capacity; the disconnector is intended for isolation, not fault interruption. Dimensions: 70 mm deep, 76.2 mm wide (3 inches), 130 mm high. The front terminal arrangement means all power and control connections are accessible from the front — no rear access needed. The 3-pole design fits standard 3-phase distribution panels.","metaTitle":"Siemens 3VA1163-1AA36-0KH0 SENTRON Switch Disconnector, 63 A","metaDescription":"Siemens SENTRON 3VA1163-1AA36-0KH0 switch disconnector, 63 A rated continuous current, 3-pole, shunt trip STL 220-250 V DC / 208-277 V AC. Current lifecycle stage. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Limited To 1 S":"2 kA","Trip indicator":"Yes","Number of poles":"3","Product version":"in MCCB design","Voltage trigger":"Yes","lifecycle_stage":"current","Limited To 0.5 S":"2 kA","Product brand name":"SENTRON","Product designation":"Switch disconnector","Latching - endurance":"15 000","Undervoltage Release":"No","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Power loss [W] / maximum":"38 W","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Rated continuous current Iu":"63 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Shunt trip (STL)","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Number of CO contacts / for auxiliary contacts":"3","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"Terminal connection","Arrangement of electrical connectors / for main current circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=210191&mlfb=3VA1163-1AA36-0KH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1163-1AA36-0KH0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1163-1AA36-0KH0 and how is it quoted for volume?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for volume pricing and current availability; lead time and price are confirmed at quote time."},{"question":"What is the rated continuous current of this switch disconnector?","answer":"Rated continuous current Iu is 63 A."},{"question":"What compliance documentation is available for 3VA1163-1AA36-0KH0?","answer":"As a Siemens SENTRON product, it carries CE marking and is designed to IEC 60947-3 standards for switch-disconnectors. RoHS and REACH declarations are available from Siemens. The IP40 front protection rating is verified per IEC 60529."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1163-1AA36-0KH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1163-1AA36-0KH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}