{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1163-4ED16-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1163-4ED16-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1163-4ED16-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1163-4ED16-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1163-4ED16-0AA0, molded case circuit breaker, 1-pole, 63 A at 40 °C, TM210 release, interrupting rating 75.6 kA at 240 V AC.","salesMarkdown":"The Siemens SENTRON 3VA1163-4ED16-0AA0 is a 1-pole molded case circuit breaker (MCCB) rated 63 A at 40 °C, with a TM210 thermal-magnetic overcurrent release. It's built for line protection in distribution panels — the 25.4 mm width per pole keeps the footprint tight on a DIN rail, and the interrupting rating of 75.6 kA at 240 V AC covers high-fault service entrance or feeder applications. The 63 A current rating holds across 40–50 °C ambient, then derates to 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, and 58 A at 70 °C — so in a hot panel you lose about 5 A at the top end. The 75.6 kA interrupting at 240 V AC is the headline number for North American service; at 415 V AC it's 9 kA, which still clears most European distribution faults.","metaTitle":"Siemens 3VA1163-4ED16-0AA0 SENTRON MCCB, 63 A, 1-Pole, 240 V","metaDescription":"Siemens SENTRON 3VA1163-4ED16-0AA0 molded case circuit breaker, 63 A at 40 °C, 1-pole, 240 V 75.6 kA interrupting. TM210 release. Active lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"25.4 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"75.6 kA","at 415 V":"9 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"62 A","at 60 °C":"61 A","at 65 °C":"60 A","at 70 °C":"58 A","Depth [In]":"2.76 in","Width [In]":"1 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"1","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"5.77 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"500 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"415 V","operating voltage / at DC / rated value":"125 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"No","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"S","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"box terminal on both sides","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/28adf7984f3ac241146b7333f53f367e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=38794&mlfb=3VA1163-4ED16-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1163-4ED16-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting rating of 3VA1163-4ED16-0AA0 at 240 V?","answer":"75.6 kA at 240 V AC. At 415 V AC it's 9 kA."},{"question":"What is the width of this MCCB?","answer":"25.4 mm (1 inch) per pole — single pole fits a standard 1-inch DIN-rail space."},{"question":"Where can I buy 3VA1163-4ED16-0AA0?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1163-4ED16-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1163-4ED16-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}