{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1163-4EF32-0CH0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1163-4EF32-0CH0","canonicalUrl":"https://aoctrl.com/siemens/3VA1163-4EF32-0CH0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1163-4EF32-0CH0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1163-4EF32-0CH0, molded case circuit breaker, 3-pole, 63 A rated, TM240 thermal-magnetic release, 121 kA breaking at 240 V AC, undervoltage release, IP40 front.","salesMarkdown":"## MCCB for line protection — 63 A, 121 kA IC at 240 V It carries a continuous current Iu of 63 A at 40 °C ambient, with a thermal-magnetic TM240 overcurrent release. The interrupting ratings hit 121 kA at 240 V AC and 75.6 kA at 415 V AC — enough for high-fault utility feeds or transformer secondaries. The 3-pole body includes an undervoltage release (UVR) and a 2-auxiliary + 1 trip-alarm switch HQ contact block, so it drops the load on loss of control voltage and signals the trip remotely.","metaTitle":"Siemens 3VA1163-4EF32-0CH0 SENTRON MCCB, 63 A, 121 kA at 240","metaDescription":"Siemens 3VA1163-4EF32-0CH0 SENTRON molded case circuit breaker, 63 A rated, 121 kA breaking at 240 V, 3-pole, TM240 release, undervoltage release included. Active production — quot","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"121 kA","at 415 V":"75.6 kA","at 440 V":"52.5 kA","at 690 V":"11.9 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"60.48 A","at 60 °C":"59.22 A","at 65 °C":"57.96 A","at 70 °C":"56.7 A","Trip indicator":"Yes","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches + 1 trip alarm switch HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"63 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB24","Design of the overcurrent release":"TM240","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"63 A","Adjustable response value current / li max.":"630 A","Adjustable response value current / li min.":"315 A","Adjustable response value current / lr min.":"44 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"3","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AB12","Switching capacity class of the circuit breaker":"S","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e25373a737e64e881c05aca746e8df94.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=456295&mlfb=3VA1163-4EF32-0CH0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1163-4EF32-0CH0/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of 3VA1163-4EF32-0CH0?","answer":"Rated continuous current Iu 63 A at 40 °C, breaking capacity 121 kA at 240 V AC and 75.6 kA at 415 V AC, 3-pole, TM240 thermal-magnetic release, undervoltage release included."},{"question":"Where can I buy 3VA1163-4EF32-0CH0?","answer":"This MCCB is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time."},{"question":"What is the depth of 3VA1163-4EF32-0CH0?","answer":"The depth is 70 mm, with a width of 76.2 mm and height of 130 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1163-4EF32-0CH0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1163-4EF32-0CH0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}