{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1163-5ED32-0AA0-ZD00","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1163-5ED32-0AA0-ZD00","canonicalUrl":"https://aoctrl.com/siemens/3VA1163-5ED32-0AA0-ZD00","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1163-5ED32-0AA0-ZD00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 160, breaking capacity class M, 3-pole, line protection TM210, In=63A, Icu=55kA @ 415V, nut keeper kit for DC Power OEM in China.","salesMarkdown":"The Siemens 3VA1163-5ED32-0AA0-ZD00 is a 3-pole IEC frame 160 molded case circuit breaker (MCCB) with breaking capacity class M, meaning it delivers 55 kA Icu at 415 V — enough for high-fault industrial distribution panels where the upstream transformer or bus can push serious energy into a bolted fault. The 63 A fixed thermal-magnetic trip (TM210) with Ir = 63 A and Ii = 10 × In covers feeder and motor branch protection in a single device, no add-on trip unit needed. The nut keeper kit and DC Power OEM designation point to a variant built for Chinese OEM panel builders integrating into DC power systems; the breaker itself is a standard AC-rated IEC device, but the kit and OEM marking align with a specific production run. For selective coordination downstream, the TM210 trip curve with Ii = 10 × In (630 A magnetic pickup) gives a wide margin above motor inrush, reducing nuisance trips on start-up while still clearing hard faults fast. Mounts on standard DIN rail or panel-mount via the frame 160 footprint, with the nut keeper kit securing the terminals against vibration in OEM equipment.","metaTitle":"Siemens 3VA1163-5ED32-0AA0-ZD00 Circuit Breaker, 63A, 55kA","metaDescription":"Siemens 3VA1163-5ED32-0AA0-ZD00 IEC frame 160 MCCB, 3-pole, 63A TM210, 55kA @ 415V. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/948acda81a621b4f23d5ffce161f24cc.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1667813&mlfb=3VA1163-5ED32-0AA0-ZD00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1163-5ED32-0AA0-ZD00/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1163-5ED32-0AA0-ZD00?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of this breaker?","answer":"The 3VA1163-5ED32-0AA0-ZD00 has an Icu of 55 kA at 415 V (breaking capacity class M), suitable for high-fault industrial distribution panels."},{"question":"What does the 'DC Power OEM in China' marking mean?","answer":"The nut keeper kit and DC Power OEM designation indicate this variant was built for Chinese OEM panel builders integrating into DC power systems, but the breaker itself is a standard AC-rated IEC device."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1163-5ED32-0AA0-ZD00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1163-5ED32-0AA0-ZD00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}