{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1163-5ED32-0JA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1163-5ED32-0JA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1163-5ED32-0JA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1163-5ED32-0JA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1 series, molded case circuit breaker (MCCB), order code 3VA1163-5ED32-0JA0, 3-pole, 63 A rated current, 187 kA breaking capacity at 240 V AC, TM210 thermal-magnetic release.","salesMarkdown":"The Siemens 3VA1163-5ED32-0JA0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for 63 A continuous at 40 °C, with a TM210 thermal-magnetic trip unit — meaning it handles overload and short-circuit protection in one package, no external relay needed. Breaking capacity hits 187 kA at 240 V AC, dropping to 121 kA at 415 V and 75.6 kA at 440 V — enough headroom for most industrial distribution panels where fault currents can spike on transformer secondaries. At 40 °C ambient the breaker carries a full 63 A; at 55 °C it's still good for 62 A, and at 70 °C it holds 58 A — minimal derating curve, which simplifies panel layout when the breaker sits near other heat sources. Dimensions are 70 mm deep by 76.2 mm wide by 130 mm high, so it fits standard Siemens 3VA1 panel cutouts and busbar systems without adaptor plates. ## What the TM210 release and shunt trip mean for commissioning The TM210 overcurrent release is a fixed thermal-magnetic type — thermal element for overload, magnetic for short-circuit. No interchangeable trip block, so the 63 A rating is locked to this unit.","metaTitle":"Siemens 3VA1163-5ED32-0JA0 SENTRON MCCB, 63 A, 3-Pole, 187 k","metaDescription":"Siemens 3VA1163-5ED32-0JA0 SENTRON molded case circuit breaker, 63 A rated at 40 °C, 3-pole, TM210 release, 187 kA breaking capacity at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"75.6 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"62 A","at 60 °C":"61 A","at 65 °C":"60 A","at 70 °C":"58 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"Yes","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"17.3 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Of The Supplied Basic Switch":"3VA11635ED320AA0","Design Of The Auxiliary Release":"shunt trip (STL)","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Of The Integrated Auxiliary Trip Unit":"3VA9688-0BL32","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=59329&mlfb=3VA1163-5ED32-0JA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1163-5ED32-0JA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the 3VA1163-5ED32-0JA0?","answer":"This part is sourced and quoted to order through independent distribution against an RFQ. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of this MCCB at 240 V?","answer":"187 kA at 240 V AC, which covers high-fault installations like transformer secondaries or large motor control centers."},{"question":"Will the 3VA1163-5ED32-0JA0 drop into a panel designed for the 3VA1110-5ED32-0AA0?","answer":"Both are 3-pole SENTRON 3VA1 frame breakers with the same 70 mm depth and 76.2 mm width, so the physical footprint is identical. The main difference is the current rating — 63 A on this unit versus a lower rating on the 3VA1110 variant — so busbar and lug sizing should be verified for the higher continuous current."},{"question":"What compliance documentation is available for this breaker?","answer":"As a Siemens SENTRON MCCB, it carries the usual IEC/EN 60947-2 certifications. Specific compliance documentation (RoHS, REACH, UL listing) is available on request at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1163-5ED32-0JA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1163-5ED32-0JA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}