{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1163-5EE32-0DC0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1163-5EE32-0DC0","canonicalUrl":"https://aoctrl.com/siemens/3VA1163-5EE32-0DC0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1163-5EE32-0DC0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1163-5EE32-0DC0, 3-pole molded case circuit breaker, 63 A rated continuous current (Iu), TM220 thermal-magnetic release, interrupting ratings 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, 17 kA at 690 V.","salesMarkdown":"The Siemens SENTRON 3VA1163-5EE32-0DC0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current at 40 °C, with a TM220 thermal-magnetic overcurrent release and an integrated undervoltage release (UVR). The interrupting capacity is the headline here: 187 kA at 240 V AC, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V — numbers that place it in the high-fault tier for industrial distribution panels where available fault current exceeds 100 kA. ## Thermal derating and release behavior The TM220 release holds 63 A flat from 40 °C through 50 °C, then begins to step down: 60.48 A at 55 °C, 59.22 A at 60 °C, 57.96 A at 65 °C, and 56.7 A at 70 °C. The UVR (undervoltage release) is built in, so a voltage dip below the dropout threshold opens the breaker; verify your control voltage matches the release coil rating from the order code suffix. No phase failure detection or ground fault monitoring on this version. ## Physical fit and auxiliaries Footprint is 76.2 mm wide (roughly 3 inches — standard MCCB pitch), 130 mm tall, 70 mm deep. It carries two HQ auxiliary switches (3VA9608-0BB25) integrated, so you get status feedback without a separate add-on module. The UVR is factory-fitted; no voltage trigger or communication function on this order code.","metaTitle":"Siemens 3VA1163-5EE32-0DC0 SENTRON MCCB, 63 A, 187 kA at 240","metaDescription":"Siemens SENTRON 3VA1163-5EE32-0DC0 molded case circuit breaker, 63 A rated continuous current, 187 kA interrupting at 240 V. TM220 release, UVR included. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"75.6 kA","at 690 V":"17 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"60.48 A","at 60 °C":"59.22 A","at 65 °C":"57.96 A","at 70 °C":"56.7 A","Trip indicator":"No","Number of poles":"3","Product version":"Line protection","Voltage trigger":"No","lifecycle_stage":"current","Product brand name":"SENTRON","Product designation":"Molded case circuit breaker","Latching - endurance":"15 000","Undervoltage Release":"Yes","Communication Function":"No","Phase failure detection":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","Auxiliary contact version":"2 auxiliary switches HQ","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Rated continuous current Iu":"63 A","Rated insulation voltage Ui":"800 V","Design of the auxiliary release":"Undervoltage release (UVR)","Ground fault monitoring version":"Without","Of The Integrated Auxiliary Trip":"3VA9608-0BB25","Design of the overcurrent release":"TM220","Design of short-circuit protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","Protection class IP / on the front":"IP40","Reference code / acc. to DIN EN 81346-2":"Q","Adjustable response value time / tr max.":"1","Adjustable response value time / tr min.":"1","Max. rated operational voltage Ue with DC":"500 V","Undervoltage Release With Leading Contact":"No","Product extension / optional / motor drive":"Yes","Adjustable response value current / Ir max.":"63 A","Adjustable response value current / li max.":"630 A","Adjustable response value current / li min.":"630 A","Adjustable response value current / lr min.":"44 A","Neutral conductors / upgradeable/retrofittable":"No","Number of CO contacts / for auxiliary contacts":"2","Protective function of the overcurrent release":"LI","Of The Integrated Auxiliary Switch/Alarm Switch":"3VA9988-0AA12","Switching capacity class of the circuit breaker":"M","Max. rated operational current of the frame size":"160 A","Max. rated operational voltage Ue with AC 50/60Hz":"690 V","Type of electrical connection / for main current circuit":"lug terminal","Arrangement of electrical connectors / for main current circuit":"Front terminal","Type of connectable conductor cross-section, connection screw, width x thickness , max.":"17 x 6.5","Type of connectable conductor cross-section, connection screw, width x thickness , min.":"12 x 0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=466760&mlfb=3VA1163-5EE32-0DC0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1163-5EE32-0DC0/alternatives.json"},"ai":{"faq":[{"question":"What are the interrupting ratings for 3VA1163-5EE32-0DC0?","answer":"187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V — these are the short-circuit breaking capacities at those voltages."},{"question":"Where can I buy 3VA1163-5EE32-0DC0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."},{"question":"What overcurrent release does 3VA1163-5EE32-0DC0 use?","answer":"It uses a TM220 thermal-magnetic release — a fixed-trip design with thermal protection for overloads and magnetic instantaneous for short circuits."},{"question":"Does 3VA1163-5EE32-0DC0 include an undervoltage release?","answer":"Yes, it is factory-equipped with an undervoltage release (UVR) as the auxiliary release type."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1163-5EE32-0DC0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1163-5EE32-0DC0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}