{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1163-5GE42-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1163-5GE42-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1163-5GE42-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1163-5GE42-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1163-5GE42-0AA0, molded case circuit breaker, 4-pole, 63 A, TM220 thermal-magnetic release, line protection, 187 kA at 240 V.","salesMarkdown":"Its 4-pole construction suits three-phase plus neutral applications in distribution panels or as a main disconnect in industrial switchboards. The 70 mm depth and 101.6 mm width keep it within a standard MCCB footprint, so it slots into existing SENTRON mounting bases without re-drilling gland plates. This breaker delivers 187 kA interrupting capacity at 240 V AC, dropping to 121 kA at 415 V and 75.6 kA at 440 V — figures that give the panel designer headroom for high-fault utility feeds without cascading upstream. Above 50 °C it derates gradually: 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, 58 A at 70 °C.","metaTitle":"Siemens 3VA1163-5GE42-0AA0 SENTRON MCCB, 63 A, 4-Pole, TM220","metaDescription":"Siemens 3VA1163-5GE42-0AA0 SENTRON molded case circuit breaker, 63 A rated, 4 poles, TM220 release, 187 kA at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"101.6 mm","Height":"130 mm","Maximum":"630 A","Minimum":"630 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"75.6 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"63 A","at 45 °C":"63 A","at 50 °C":"63 A","at 55 °C":"62 A","at 60 °C":"61 A","at 65 °C":"60 A","at 70 °C":"58 A","Depth [In]":"2.76 in","Width [In]":"4 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"4","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"17.3 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"63 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM220","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","design of the N-conductor protection":"100%","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"600 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=464859&mlfb=3VA1163-5GE42-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1163-5GE42-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1163-5GE42-0AA0 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings for 3VA1163-5GE42-0AA0?","answer":"Rated continuous current 63 A at 40 °C, 4 poles, TM220 thermal-magnetic release, interrupting capacity 187 kA at 240 V AC, 121 kA at 415 V, 75.6 kA at 440 V, 17 kA at 500 V and 690 V."},{"question":"What is the depth of this MCCB?","answer":"The depth is 70 mm (2.76 in)."},{"question":"What is the width of this MCCB?","answer":"The width is 101.6 mm (4 in)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1163-5GE42-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1163-5GE42-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}