{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1180-3ED32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1180-3ED32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1180-3ED32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1180-3ED32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1180-3ED32-0AA0, molded case circuit breaker, 3-pole, 80 A continuous at 40 °C, TM210 thermal-magnetic release, interrupting capacity 75.6 kA at 240 V.","salesMarkdown":"The Siemens SENTRON 3VA1180-3ED32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated 80 A continuous at 40 °C, fitted with a TM210 thermal-magnetic release for line protection. It's designed for distribution panels and motor branch circuits where you need adjustable thermal pickup and fixed magnetic instant trip — the TM210 gives you a 2:1 thermal adjustment range (0.7–1.0× In) and a fixed magnetic trip at 10× In, so it handles motor inrush without nuisance trips on the thermal side. Interrupting capacity runs 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at 500 V and 690 V — that covers most industrial service entrances and sub-distribution boards without needing a current-limiting fuse upstream. At 130 mm high, 76.2 mm wide, and 70 mm deep, this MCCB fits a standard 3-pole breaker slot in most Siemens SENTRON panelboards and switchgear. The 76.2 mm width matches the 3-inch (76.2 mm) modular spacing common in North American panel schedules — you can swap it into an existing 3-pole position without re-drilling the mounting plate. Above 50 °C it drops linearly: 78 A at 55 °C, 77 A at 60 °C, 75 A at 65 °C, 74 A at 70 °C. If your panel ambient hits 70 °C, you've still got 74 A of headroom. In a sealed NEMA 4X box with multiple breakers, add those losses up for the thermal budget.","metaTitle":"Siemens 3VA1180-3ED32-0AA0 SENTRON MCCB, 80 A, 3-Pole","metaDescription":"Siemens SENTRON 3VA1180-3ED32-0AA0 molded case circuit breaker, 80 A continuous, 3-pole, TM210 release. Interrupting capacity 75.6 kA at 240 V. Current lifecycle. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"800 A","Minimum":"800 A","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 500 V":"11.9 kA","at 690 V":"11.9 kA","at 40 °C":"80 A","at 45 °C":"80 A","at 50 °C":"80 A","at 55 °C":"78 A","at 60 °C":"77 A","at 65 °C":"75 A","at 70 °C":"74 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"19.2 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Continuous Current / Rated Value":"80 A","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Continuous Current / Rated Value / Maximum":"160 A","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"N","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0a02e45e528156b50d06c6048932ad72.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=333448&mlfb=3VA1180-3ED32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1180-3ED32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3VA1180-3ED32-0AA0?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the interrupting capacity of 3VA1180-3ED32-0AA0 at 240 V?","answer":"75.6 kA at 240 V. At 415 V it's 52.5 kA, at 440 V it's 32 kA, and at 500 V and 690 V it's 11.9 kA."},{"question":"Does 3VA1180-3ED32-0AA0 have a communication function or undervoltage release?","answer":"No. This variant has no communication function, no undervoltage release, no shunt trip, and no ground-fault monitoring. It's a straight thermal-magnetic breaker for line protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1180-3ED32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1180-3ED32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}