{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1180-3EF32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1180-3EF32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1180-3EF32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1180-3EF32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1180-3EF32-0AA0, molded case circuit breaker, 3-pole, 80 A (40 °C), TM240 overcurrent release, breaking capacity 75.6 kA at 240 V AC, 70 mm depth.","salesMarkdown":"The front face is IP40 protected, which means it's sealed against tools and small wires but not against moisture ingress; keep it in a dry enclosure. This MCCB delivers 75.6 kA interrupting capacity at 240 V AC, dropping to 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at both 500 V and 690 V. For a 480 V panel (common in North American industrial), the 32 kA at 440 V is the closest published figure — the actual SCCR at 480 V will be between that and the 11.9 kA at 500 V, so verify coordination with the upstream transformer's fault current. Above that, it derates linearly: 78 A at 55 °C, 77 A at 60 °C, 75 A at 65 °C, and 74 A at 70 °C. Mounting dimensions are 130 mm height, 76.2 mm width (3 inches — standard MCCB footprint), and 70 mm depth, so it fits a typical 3-inch-wide panel cutout without surprises.","metaTitle":"Siemens 3VA1180-3EF32-0AA0 SENTRON MCCB, 80 A, 3-Pole, 70 mm","metaDescription":"Siemens SENTRON 3VA1180-3EF32-0AA0 molded case circuit breaker, 80 A at 40 °C, 3-pole, TM240 release. Breaking capacity 75.6 kA at 240 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"75.6 kA","at 415 V":"52.5 kA","at 440 V":"32 kA","at 500 V":"11.9 kA","at 690 V":"11.9 kA","at 40 °C":"80 A","at 45 °C":"80 A","at 50 °C":"80 A","at 55 °C":"78 A","at 60 °C":"77 A","at 65 °C":"75 A","at 70 °C":"74 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"19.2 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM240","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"N","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/70eaa6a593b552c5055e220b34aeeed3.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=400115&mlfb=3VA1180-3EF32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1180-3EF32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3VA1180-3EF32-0AA0?","answer":"Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels."},{"question":"What is 3VA1180-3EF32-0AA0's listed depth?","answer":"The listed depth is 70 mm (2.76 inches)."},{"question":"What is 3VA1180-3EF32-0AA0's listed width?","answer":"The listed width is 76.2 mm (3 inches)."},{"question":"Will 3VA1180-3EF32-0AA0 drop into a panel specified around 3VA1110-5ED32-0AA0 without rewiring?","answer":"Both are 3-pole SENTRON MCCBs with the same 76.2 mm width and 130 mm height, so the panel cutout and bus-bar spacing are identical. The 3VA1180-3EF32-0AA0 carries a higher 80 A rating versus the 3VA1110-5ED32-0AA0, and uses a TM240 release — verify the trip curve matches your coordination study. Wiring terminations are the same form factor; no rewiring needed if the conductor sizing supports 80 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1180-3EF32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1180-3EF32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}