{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1180-4EE32-0AA0-ZD00","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1180-4EE32-0AA0-ZD00","canonicalUrl":"https://aoctrl.com/siemens/3VA1180-4EE32-0AA0-ZD00","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1180-4EE32-0AA0-ZD00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 160, breaking capacity class S, Icu=36kA @ 415V, 3-pole, line protection TM220, ATFM, In=80A, overload Ir=56A...80A, short-circuit Ii=10 x In.","salesMarkdown":"The 3VA1180-4EE32-0AA0-ZD00 is a 3-pole IEC molded-case circuit breaker in the 3VA1 frame, rated In=80A with a TM220 thermal-magnetic trip unit (ATFM). Overload protection is adjustable Ir=56A to 80A via the TM220 dial; short-circuit protection is fixed at Ii=10 x In (800A). That fixed magnetic threshold means it is suited for general distribution and moderate motor starting, not high-inrush transformer or capacitor loads where a higher Ii setting would be needed to avoid nuisance tripping. The lifecycle stage is current. The -ZD00 suffix indicates a DC Power OEM variant with a nut keeper kit.","metaTitle":"3VA1180-4EE32-0AA0-ZD00 Circuit Breaker, 80A, Icu=36kA at 41","metaDescription":"3VA1180-4EE32-0AA0-ZD00 circuit breaker, 3VA1 IEC frame 160, breaking capacity class S, Icu=36kA @ 415V, 3-pole, TM220, ATFM, In=80A, overload Ir=56A-80A, short-circuit Ii=10xIn. C","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2c17cf1ba7e4b618822a8e2211128a3f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1667842&mlfb=3VA1180-4EE32-0AA0-ZD00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1180-4EE32-0AA0-ZD00/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this breaker?","answer":"Icu=36kA at 415V AC, which is the maximum short-circuit current it can safely interrupt at that voltage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1180-4EE32-0AA0-ZD00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1180-4EE32-0AA0-ZD00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}