{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1180-5ED32-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1180-5ED32-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3VA1180-5ED32-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1180-5ED32-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 3VA1180-5ED32-0AA0, 3-pole molded case circuit breaker, 80 A at 40 °C, TM210 thermal-magnetic release, 187 kA interrupting at 240 V.","salesMarkdown":"The 3VA1180-5ED32-0AA0: This is a Siemens SENTRON 3VA1 molded case circuit breaker, 3-pole, rated 80 A continuous at 40 °C with a TM210 thermal-magnetic trip unit. It's built for line protection — think main feeder or large subfeed in a distribution panel, not motor-starting duty. ## Ratings that matter for the install Interrupting capacity drops as voltage climbs: 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 500 or 690 V. IP40 on the front — splash protection on the face, but the terminals are open; mount it in a dead-front enclosure or a panel with a door. Three-pole, so it occupies a single 76.2 mm module on the DIN rail or mounting plate — standard 3-pole MCCB footprint.","metaTitle":"Siemens 3VA1180-5ED32-0AA0 SENTRON MCCB, 80 A, 3-Pole, TM210","metaDescription":"Siemens 3VA1180-5ED32-0AA0 SENTRON molded case circuit breaker, 80 A at 40 °C, 3-pole, TM210 release, 187 kA at 240 V. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"70 mm","Width":"76.2 mm","Height":"130 mm","Maximum":"0 A","Minimum":"0 A","at 240 V":"187 kA","at 415 V":"121 kA","at 440 V":"75.6 kA","at 500 V":"17 kA","at 690 V":"17 kA","at 40 °C":"80 A","at 45 °C":"80 A","at 50 °C":"80 A","at 55 °C":"78 A","at 60 °C":"77 A","at 65 °C":"75 A","at 70 °C":"74 A","Depth [In]":"2.76 in","Width [In]":"3 in","Height [In]":"5.12 in","Trip Indicator":"No","Number Of Poles":"3","Voltage Trigger":"No","lifecycle_stage":"current","Product Brand Name":"SENTRON","Product Designation":"Molded case circuit breaker","Undervoltage Release":"No","Design Of The Product":"Line protection","Communication Function":"No","During Storage / Maximum":"80 °C","During Storage / Minimum":"-40 °C","power loss [W] / maximum":"19.2 W","During Operation / Maximum":"70 °C","During Operation / Minimum":"-25 °C","Other Measurement Function":"No","Ground-Fault Monitoring Version":"Without","Insulation Voltage / Rated Value":"800 V","Design Of The Overcurrent Release":"TM210","Design Of Short-Circuit Protection":"For switching power values in DC networks, see the 3VA molded case circuit breaker device manual; link to be found under Service & Support in the last chapter","protection class IP / on the front":"IP40","Product Function / Grounding Protection":"No","operating voltage / at AC / rated value":"690 V","operating voltage / at DC / rated value":"500 V","reference code / according to IEC 81346-2":"Q","Product Extension / Optional / Motor Drive":"Yes","Protection Function Of The Overcurrent Release":"LI","number of CO contacts / for auxiliary contacts":"0","Switching Capacity Class Of The Circuit Breaker":"M","Mechanical Service Life (Operating Cycles) / Typical":"20 000","Type Of Electrical Connection / For Main Current Circuit":"nut keeper kit on both ends","Arrangement Of Electrical Connectors / For Main Current Circuit":"Front terminal"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=123853&mlfb=3VA1180-5ED32-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1180-5ED32-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the interrupting rating of this MCCB at 240 V?","answer":"187 kA at 240 V, which drops to 121 kA at 415 V and 75.6 kA at 440 V. At 500 V and 690 V it's rated 17 kA."},{"question":"How do I get current pricing and availability for 3VA1180-5ED32-0AA0?","answer":"Submit an RFQ through the distributor. This part is sourced to order through independent distribution channels; availability and current pricing are confirmed at quote time."},{"question":"Will 3VA1180-5ED32-0AA0 drop into a panel specified around 5SQ2370-2YA05 without rewiring?","answer":"The 5SQ2370-2YA05 is a different manufacturer's MCCB. While both are 3-pole 80 A class breakers, the mounting hole pattern, busbar spacing, and terminal layout may differ. Physical fit is not guaranteed — verify the footprint against your panel layout before ordering."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1180-5ED32-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1180-5ED32-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}