{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3VA1180-5GD42-0AA0-ZD00","brand":"Siemens","brandSlug":"siemens","productSlug":"3VA1180-5GD42-0AA0-ZD00","canonicalUrl":"https://aoctrl.com/siemens/3VA1180-5GD42-0AA0-ZD00","factsUrl":"https://aoctrl.com/api/mcp/products/3VA1180-5GD42-0AA0-ZD00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3VA1 IEC frame 160 MCCB, 4-pole, 80A, breaking capacity class M Icu=55kA @ 415V, TM210 line protection, FTFM, fixed short-circuit protection Ii=10 x In, N conductor protection 100%, nut keeper kit for DC Power OEM in China.","salesMarkdown":"## What this 3VA1 breaker carries The Siemens 3VA1180-5GD42-0AA0-ZD00 is a 4-pole IEC frame 160 molded-case circuit breaker with an 80 A rating and a 55 kA breaking capacity at 415 V (class M). Protection is handled by a TM210 thermal-magnetic trip unit with fixed overload Ir=80 A and fixed short-circuit pickup Ii=10 x In (800 A). The neutral conductor is protected at 100%, and the FTFM (fixed thermal, fixed magnetic) design means no field-adjustable dials — what you order is what you get for coordination studies.","metaTitle":"Siemens 3VA1180-5GD42-0AA0-ZD00 Circuit Breaker, 80A, 55kA @","metaDescription":"Siemens 3VA1180-5GD42-0AA0-ZD00 IEC frame 160 MCCB, 80A, 55kA breaking capacity @ 415V. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/59618aece06b4a284568b9efaadf930d.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1667855&mlfb=3VA1180-5GD42-0AA0-ZD00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3VA1180-5GD42-0AA0-ZD00/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of this breaker?","answer":"It carries a 55 kA breaking capacity (Icu) at 415 V, class M, on an IEC frame 160 platform."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3VA1180-5GD42-0AA0-ZD00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3VA1180-5GD42-0AA0-ZD00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}